The invention and development of blood gas analysis apparatus.
نویسنده
چکیده
In 1953, the doctor draft interrupted Dr. Severinghaus' anesthesia and physiology training and sent him to the National Institutes of Health as director of anesthesia research at the newly opened Clinical Center. He developed precise laboratory partial pressure of carbon dioxide (PCO(2)) and pH analysis to investigate lung blood gas exchange during hypothermia. Constants for carbon dioxide solubility and pK' were more accurately determined. In August 1954, he heard Richard Stow describe invention of a carbon dioxide electrode and immediately built one, improved its stability, and tested its response characteristics. In April 1956, he also heard Leland Clark reveal his invention of an oxygen electrode. Dr. Severinghaus obtained one and constructed a stirred cuvette in which blood partial pressure of oxygen (PO(2)) could be accurately measured. Technician Bradley and Dr. Severinghaus combined these, making the first blood gas analysis system in 1957 and 1958, and shortly thereafter, they added a pH electrode. Blood gas analyzers rapidly developed commercially. Dr. Severinghaus collaborated with Astrup and other Danes on the Haldane and Bohr effects and their concepts of base excess during two sabbaticals in Copenhagen. Work with both Astrup and Roughton on the oxygen dissociation curve led Dr. Severinghaus to devise a modified Hill equation that closely fit their new, better human oxygen dissociation curve and a blood gas slide rule that solved oxygen dissociation curve, PCO(2), pH, and acid-base questions. Blood gas analysis revolutionized both clinical medicine and cardiorespiratory and metabolic physiology.
منابع مشابه
Experimental Investigation of Natural Gas Components During Gas Hydrate Formation in Presence or Absence of the L-Tyrosine as a Kinetic Inhibitor in a Flow Mini-loop Apparatus
Hydrates are crystalline compounds similar to ice, with guest molecules like methane and ethane trapped inside cavities or cages formed by the hydrogen bounded framework of water molecules. These solid compounds give rise to problems in the natural gas oil industry because they can plug pipelines and process equipments. Low dosage hydrate inhibitors are a recently developed hydrate control tech...
متن کاملAnatomical parameters of cardiopulmonary system, venous blood pCO2and pO2tensions and the development of ascites syndrome in two genetic line chickens that are differing in their growth rate
The present study was designed to examine the anatomical parameters of the cardiopulmonary system, the function of venous blood gas parameters and the development of ascites incidence in two genetic line chickens. Three hundred forty day-old chickens from two pure broiler breeder lines, which were different in their growth rate and susceptibility to ascites syndrome were obtained. The relative ...
متن کاملThe Hare-clarke Controversy over the Invention of the Improved Gas Blowpipe
Credit for the initial invention of the gas blowpipe has been marked by an unusually large amount of controversy (1), involving bitter charges of plagiarism and intellectual dishonesty. An example of this involves the American chemist Robert Hare,1781-1858 (2), who claimed that Edward Clarke, Professor of Mineralogy at Cambridge University (3), had falsely taken credit for the invention of the ...
متن کاملDetermination of Neonatal Prognosis Based on Umbilical Vein Blood Gas in Hakim Hospital of Neyshabur, Iran during 2017-2018
Background: In order to determine the prognosis of neonates, it is recommended to use umbilical gas analysis in all high-risk pregnancies. However, utilizing umbilical gas analysis and Apgar score together is very helpful for determining the mortality rate confidence interval. Therefore, in this study, we investigated the application of umbilical gas analysis in assessing the prognosis of infan...
متن کاملCan we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?
Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 97 1 شماره
صفحات -
تاریخ انتشار 2002