Relaxed versus activated stump muscles during casting for trans-tibial prostheses.

نویسندگان

  • M Lilja
  • S Johansson
  • T Oberg
چکیده

In prosthetic practice, the question often arises as to whether the hand cast should be made from a contracted or from a non-contracted amputation stump. To elucidate this question, the authors have performed a study to quantify the volume difference between these 2 conditions, and to relate the differences to prosthetic fitting. Sixteen (16) trans-tibial amputees participated in the study. All of them were fitted with an ICEROSS silicone socket. Electromyographic studies, with electrodes attached to the anterior tibial and medial gastrocnemius muscles, were carried out to determine muscle contraction levels. Volume determinations were made with the CAPOD laser scanning system. Measurements were performed with and without the silicone liner on the stump. Without a silicone liner, the volume of the stump increased by 5.8% (SD=5.3) as the muscles contracted. This increase was statistically significant. With the liner donned the volume increased 3.5% (SD=3.3). This increase was also statistically significant. The volume of the prosthetic socket was also compared with the stump volume with a silicone liner on. For the relaxed stump, the difference was 1.8% (SD=10.1), and for the contracted stump -1.7% (SD=11.3). Neither difference was statistically significant. The importance of these volume changes and how they influence stiffness of the coupling between the stump and the socket are discussed. It is concluded, that the observed difference in volume between a contracted and a non-contracted stump are large enough to be considered by the prosthetist in his decision on how to make a hand cast.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sand-casting technique for trans-tibial prostheses.

A sand-casting technique for trans-tibial sockets was applied to 28 amputees, and the prosthetic fit observed through transparent check sockets. The results were better than historical reports of fittings with plaster of Paris casting by qualified prosthetists. The fit was consistently and evenly larger than the stump, but total contact could be achieved by applying three (two to five) stump so...

متن کامل

Morphological changes during early trans-tibial prosthetic fitting.

Morphological changes in the amputation stump may have serious implications regarding the suspension and fit of the prosthetic socket. In an earlier study (Lilja and Oberg, 1997) the authors have shown that the volume of the trans-tibial amputation stump decreases according to a negative power function after amputation, and that the stump volume does not stabilise until four months after the op...

متن کامل

Stump length as related to atrophy and strength of the thigh muscles in trans-tibial amputees.

Stump length and the thigh muscles strength of the amputated limb are among the major factors influencing outcome of prosthetic rehabilitation of trans-tibial amputees. In the present study the authors evaluated and compared the strength of quadriceps and hamstrings muscles of both limbs in trans-tibial amputees, as measured by means of an electrical dynamometer. The obtained results showed tha...

متن کامل

Engineering a trans-tibial prosthetic socket for the lower limb amputee.

INTRODUCTION This review addresses the different prosthetic socket designs for trans-tibial amputees, the biomechanics behind the designs and the current state of the field. Of particular focus is the classic patella-tendon bearing (PTB) socket and the more recent sockets manufactured using pressure casting techniques and the theory, biomechanics and clinical implications of the two designs. Me...

متن کامل

Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.

The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 1999