Report on Calorimetric Studies at the Nhe Laboratory in Sapporo, Japan

نویسنده

  • MELVIN H. MILES
چکیده

Experiments using China Lake type calorimetric cells produced excess power in three out of three experiments and no excess power in three control studies. A detailed analysis is presented for two experiments using the China Lake cells. Anomalous thermistor signals in Cell A suggest the emission of electromagnetic radiation from the active palladium cathode. Experiments in Fleischmann-Pons type calorimetric cells produced excess power in six out of eight experiments. These studies involved palladium alloy cathodes, co-deposition of palladium and deuterium from the solution, and electromigration using thin palladium wires.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calorimetric Studies of Palladium Alloy Cathodes Using Fleischmann-Pons Dewar Type Cells

My first three experiments conducted at NHE using the Fleischmann-Pons (F-P) Dewar type cells investigated the Pd-Ce-B, Pd-B, and Pd-Ce alloy cathodes. Significant excess power was produced from the cells using the Pd-B and Pd-Ce alloy cathodes. The Pd-Ce-B alloy, in contrast, showed no measureable excess power effects. Previous experiments at China Lake using similar Pd-B alloy cathodes prepar...

متن کامل

Urban Canyon Microclimate and Spatial Behavior in Extreme Climate Situations (Case Study: Downtown Pedestrian Street in Northern China)

Microclimate in open space affected by the urban layout and spatial forms plays an important role in the outdoor comfort, thus the outdoor activities based on the comfort sensation will directly affected by the spatial forms. An outstanding open space should satisfy different requirements of outdoor activities and create relatively comfortable place.Most studies have been conducted on the...

متن کامل

THERMAL BEHAVIOR OF POLARIZED Pd/D ELECTRODES PREPARED BY CO-DEPOSITION

The thermal behavior of a polarized Pd+D electrode prepared by the co-deposition technique and serving as the cathode in the Fleischmann-Pons (F/P) Dewar-type electrochemical cell/calorimeter was investigated at the NHE Laboratory in Sapporo, Japan. These measurements show that (i) excess enthalpy is generated during and after the completion of the co-deposition process, (ii) rates of excess en...

متن کامل

Erratum to: Liver elasticity measurement before and after biliary drainage in patients with obstructive jaundice: a prospective cohort study

Author details Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan. Department of Gastroenterology and Hepatology, Center for Digestive Disease, University of Miyazaki, 5200 Kihara, Kiyotake-cho, Miyazaki City 889-1692, Japan. Division of Endoscopy, Hokkaido University Hospital, Sapporo, Hokkaido, Japan. Division of Laboratory and Transfusion Me...

متن کامل

Vulnerability assessment of surface water quality with an innovative integrated multi-parameter water quality index (IMWQI)

The development of a surface water evaluation index is a critical factor in the assessment, restoration and protection of stream water quality. Quantifying water pollution in specific grade using dominant parameters is important, as this can explain the current state of water pollution with accuracy. As a result, an integrated multi-parameter water quality index has been developed. It is based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008