Continuous wave Doppler echocardiography and coarctation of the aorta: gradients and flow patterns in the assessment of severity.

نویسندگان

  • J S Carvalho
  • A N Redington
  • E A Shinebourne
  • M L Rigby
  • D Gibson
چکیده

Indices of the severity of coarctation derived from non-invasive Doppler echocardiography were compared with measurements derived from cardiac catheterisation and angiography. In 24 Doppler studies from 17 children instantaneous peak systolic and diastolic gradients and time to half peak systolic and diastolic velocities were compared with the ratio of the coarctation diameter to the diameter of descending aorta at the level of diaphragm obtained from angiographic systolic frames of the aorta. A high peak systolic gradient (greater than 40 mm Hg) or long time to half peak diastolic velocity (greater than 100 ms) (that is, maintenance of flow in diastole) were both highly specific (100%) in detecting coarctation of the aorta where the angiographic ratio was less than or equal to 0.5. Diastolic measurements, however, were more sensitive (79% both for peak diastolic gradient and for time to half peak diastolic velocity) than systolic (57% for peak systolic gradient and 64% for time to half peak systolic velocity). Even higher sensitivity (93%) was obtained when the peak systolic gradient was greater than 40 mm Hg or the time to half peak diastolic velocity was greater than 100 ms. Examination by continuous wave Doppler echocardiography is an effective non-invasive method of assessing the severity of coarctation of the aorta, particularly when systolic and diastolic events are considered together. This approach overcomes the relatively low sensitivity of peak systolic gradient alone.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous wave Doppler echocardiography after surgical repair of coarctation of the aorta.

OBJECTIVE To find how closely pressure gradients across the aortic arch derived from Doppler echocardiography reflect gradients measured by catheter after surgical repair of coarctation of the aorta. DESIGN Pressure drop across the aortic arch was measured simultaneously by continuous wave Doppler and double lumen catheter in 20 patients with repaired coarctation of the aorta. RESULTS The p...

متن کامل

Color Doppler flow mapping in patients with coarctation of the aorta: new observations and improved evaluation with color flow diameter and proximal acceleration as predictors of severity.

We performed color Doppler flow mapping in 15 patients, 1 week to 17 years old (mean 42 months), with coarctation of the aorta that was confirmed subsequently by angiography and/or surgery. Twelve patients had native coarctation and three had mild recoarctation after surgical repair. Color Doppler flow maps were analyzed with a digital analysis package and a Sony computer system. The diameter i...

متن کامل

Limitations in assessing the severity of aortic stenosis by Doppler gradients.

Continuous wave Doppler echocardiography was performed before cardiac catheterisation in 69 consecutive patients with suspected aortic stenosis. Agreement between the maximum and the mean Doppler gradients and catheterisation gradients was good. Doppler echocardiography, however, systematically underestimated the maximum and mean gradients, particularly in the high range. Stepwise regression an...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Use of continuous wave Doppler ultrasound velocimetry to assess the severity of coarctation of the aorta by measurement of aortic flow velocities.

Peak ascending and descending aortic blood flow velocities were measured using continuous wave Doppler ultrasound velocimetry in 30 children with coarctation or recoarctation of the aorta and in 13 control subjects. The results were compared with the arm to leg systolic blood pressure difference. The peak flow velocities in the descending aorta were significantly higher in the patients than in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 1990