Real-time dynamic MLC tracking for inversely optimized arc radiotherapy.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Motion compensation with MLC tracking was tested for inversely optimized arc radiotherapy with special attention to the impact of the size of the target displacements and the angle of the leaf trajectory. MATERIALS AND METHODS An MLC-tracking algorithm was used to adjust the MLC positions according to the target movements using information from an optical real-time positioning management system. Two plans with collimator angles of 45 degrees and 90 degrees , respectively, were delivered and measured using the Delta(4)(R) dosimetric device moving in the superior-inferior direction with peak-to-peak displacements of 5, 10, 15, 20 and 25 mm and a cycle time of 6s. RESULTS Gamma index evaluation for plan delivery with MLC tracking gave a pass rate higher than 98% for criteria 3% and 3 mm for both plans and for all sizes of the target displacement. With no motion compensation, the average pass rate was 75% for plan 1 and 70% for plan 2 for 25 mm peak-to-peak displacement. CONCLUSION MLC tracking improves the accuracy of inversely optimized arc delivery for the cases studied. With MLC tracking, the dosimetric accuracy was independent of the magnitude of the peak-to-peak displacement of the target and not significantly affected by the angle between the leaf trajectory and the target movements.
منابع مشابه
Management of three-dimensional intrafraction motion through real-time DMLC tracking.
Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation...
متن کاملAn experimental evaluation of the Agility MLC for motion-compensated VMAT delivery.
An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) for use in motion-compensated VMAT delivery. For five VMAT patients, dosimetric ...
متن کاملEffects of collimator angle, couch angle, and starting phase on motion‐tracking dynamic conformal arc therapy (4D DCAT)
PURPOSE The aim of this study was to find an optimized configuration of collimator angle, couch angle, and starting tracking phase to improve the delivery performance in terms of MLC position errors, maximal MLC leaf speed, and total beam-on time of DCAT plans with motion tracking (4D DCAT). METHOD AND MATERIALS Nontracking conformal arc plans were first created based on a single phase (maxim...
متن کاملDynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback
Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...
متن کاملDelivery of four‐dimensional radiotherapy with TrackBeam for moving target using a dual‐layer MLC: dynamic phantoms study
Respiratory motion has been considered a clinical challenge for lung tumor treatments due to target motion. In this study, we aimed to perform an experimental evaluation based on dynamic phantoms using MLC-based beam tracking. TrackBeam, a prototype real-time beam tracking system, has been assembled and evaluated in our clinic. TrackBeam includes an orthogonal dual-layer micro multileaf collima...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
دوره 94 2 شماره
صفحات -
تاریخ انتشار 2010