Functional evaluation of normothermic ischemia and reperfusion injury in dog kidney by combining MR diffusion-weighted imaging and Gd-DTPA enhanced first-pass perfusion.

نویسندگان

  • Ai-Shi Liu
  • Jing-Xia Xie
چکیده

PURPOSE To evaluate functional alterations of renal ischemia and reperfusion injury using MR diffusion-weighted imaging and dynamic perfusion imaging. MATERIALS AND METHODS Twelve dogs were randomly divided into four groups. Animal renal ischemia was respectively induced for 30 (group 1), 60 (group 2), 90 (group 3), and 120 (group 4) minutes by left renal artery ligation under anesthesia. Using a 1.5 T MR system, true-FISP, TSE, EPI, and DWI sequences were acquired in five different periods; specifically, pre-ischemia, onset-ischemia, late ischemia, onset-reperfusion, and post-reperfusion. Moreover, a turbo-FLASH sequence (TR/TE/TI/FA = 5.8/3.2/400 msec/10 degrees ) with a temporal resolution of 1.16 seconds was acquired. Signal intensity (SI) was measured in the cortex, outer medulla, and inner medulla of kidney. Apparent diffusion coefficient (ADC) values were calculated, and SI was plotted as a function of time. RESULTS In all animals, significant SI changes of the left kidney on T2/T2*WI were detected following ischemia-reperfusion insult compared to corresponding values of the right kidney. Following ligation, the ADC values decreased in all layers of the left kidney. Immediately after the release of ligation, ADC values in both outer and inner medulla of the left kidney remained lower than those of the right kidney in those animals which were induced with renal ischemia for 60, 90, and 120 minutes. In all groups, a uniphasic enhancement pattern was observed in the outer and inner medulla of the left kidney, accompanied by a decrease of the area under the curve. CONCLUSION Our results suggest that MR diffusion-weighted imaging and dynamic perfusion imaging are useful in identifying renal dysfunction following normothermic ischemia and reperfusion injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combining diffusion-weighted MR imaging with Gd-EOB-DTPA enhanced MR imaging improves the detection of colorectal liver metastases

Introduction: In patients with colorectal cancer, accurate assessment of the size, location and segmental distribution of liver metastases on a per-lesion basis is critical for treatment planning. Diffusion-weighted MR imaging (DW-MRI) has a high sensitivity and specificity for liver metastasis detection [1-3]. Combining DW-MRI with T1-weighted imaging after liver specific contrast medium Magaf...

متن کامل

Diffusion-weighted MR imaging of acute stroke: correlation with T2-weighted and magnetic susceptibility-enhanced MR imaging in cats.

We evaluated the temporal and anatomic relationships between changes in diffusion-weighted MR image signal intensity, induced by unilateral occlusion of the middle cerebral artery in cats, and tissue perfusion deficits observed in the same animals on T2-weighted MR images after administration of a nonionic intravascular T2 shortening agent. Diffusion-weighted images obtained with strong diffusi...

متن کامل

The value of Gd-EOB-DTPA-enhanced MR imaging in characterizing cirrhotic nodules with atypical enhancement on Gd-DTPA-enhanced MR images

PURPOSE To evaluate the utility of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in characterizing atypically enhanced cirrhotic nodules detected on conventional Gd-DTPA-enhanced MR images. MATERIALS AND METHODS We enrolled 61 consecutive patients with 88 atypical nodules seen on conventional Gd-DTPA-enhanced MR images who underwent Gd-EOB-DTPA-enhanced MRI within a 3-month period. Us...

متن کامل

Kidney storage before transplantation with the use of machine perfusion

Kidney machine perfusion kidney transplantation, machine perfusion, organ preservation, hypothermic/normothermic perfusion, ischemia/ reperfusion injury

متن کامل

Gadolinium-DTPA-enhanced MR imaging of spinal neoplasms: preliminary investigation and comparison with unenhanced spin-echo and STIR sequences.

Unenhanced T1- and T2-weighted spin-echo, short inversion time inversion recovery (STIR), and gadolinium-DTPA (Gd-DTPA)-enhanced spin-echo and STIR imaging techniques were used in 20 patients as part of a multicenter study to assess the safety and efficacy of Gd-DTPA in spinal imaging. Five patients had normal MR scans. Of those with lesions, both Gd-DTPA-enhanced T1-weighted spin-echo and unen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2003