Optical observation method for ultrasonic field using the shadowgraph introducing pulse inversion averaging

نویسنده

  • Kazuhiko Imano
چکیده

The pulse inversion averaging (PIA) method is introduced to the shadowgraph imaging system to visualize the second-harmonic component of the ultrasonic field. The principle of the PIA method is summarized and the method is customized for observing an second-harmonic ultrasonic field. An experiment of a shadowgraph with PIA using a 1-MHz concave focused transducer is conducted to evaluate the system. The fundamental component of 1MHz is suppressed more than 30 dB with respect to the second-harmonic component. With this system, both a normal shadowgraph image and a second-harmonic image are visualized in real time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Probing of ultrasonic pulses by multidirectional light

An acousto-optical reconstruction method for acoustic signals using multidirectional light diffraction by finite amplitude ultrasonic pulses is presented. When crossing the ultrasonic field, the far field diffracted laser light intensity of an incident convergent lightbeam becomes modulated in time. It is found that for special conditions, concerning direction of observation, ultrasonic frequen...

متن کامل

Schlieren and Shadowgraph Imaging in the Great Outdoors

A review is given of outdoor schlieren and shadowgraph imaging, beginning with an historical perspective. The optical principles of the sunlight shadowgraph method and schlieren observation by background distortion are discussed. Examples and illustrations are given of the visualization of outdoor thermal convection, combustion, and explosion phenomena. Jet aircraft and high-speed flight are fe...

متن کامل

A Wireless Ultrasonic Ndt Senor System

Ultrasonic condition monitoring technologies have been traditionally utilized in industrial and construction environments where structural integrity is of concern. Such techniques include active systems with either single or multiple transmit-receiver combinations used to obtain defect positioning and magnitude. Active sensors are implemented in two ways; in a thickness operation mode, or as an...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

Analysis of Power Electronic Converters Using the Developed State Space Averaging Method

Power electronic converters are non-linear time-dependent systems whose exact analysis without the use of computers is very difficult, and even using computer softwares requires a long time. Use of the state space averaging method, as will be mentioned, in addition to simplifying the analysis procedure which is a result of converting a time-dependent system to a time-independent one, reduces th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEICE Electronic Express

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2014