Sensors 2001, 1, 1-12

نویسنده

  • Ernõ Pungor
چکیده

The paper discusses the anomalies of the former interpretation of the working mechanism of the ion-selective electrodes. It was thorougly discussed why the Donnan experiment could not be applied as the theoretical background of glass electrodes. It was assumed according to the Donnan interpretation that the measurable potential is produced by the transfer of the primary ion through the membrane. Since the 1960s, the author and coworkers have been investigating the problem of what can be the reason for the potential response of the electrodes. Practical measurements in connection with the response time, surface hindered reactions etc. were interpreted. Furthermore, the energy problems according to the Gibbs theory using two electrode components were investigated. It was established that the electrodes on which chemical reactions may occur with the primary ion have a surface reaction as the chemical basis of the response. For electrodes that work on the principle of the lyotropic series, surface reactions are also involved, but their response is not always Nernstian. The energy demand is covered by the charge separation at the electrodesolution interface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: results of a 1 year multicentre feasibility study.

BACKGROUND Implantable sensors that monitor haemodynamics over time may be useful in patients with heart failure. This multicentre study assessed the feasibility of a system that has one sensor measuring absolute pressure and another measuring mixed venous oxygen saturation (SvO(2)). Both sensors were mounted on leads that were implanted in the right ventricle. METHODS Twenty-one patients wit...

متن کامل

COMPARISON OF DIFFERENT GLASS COMPOUNDS FOR INTRINSIC FIBER OPTIC TEMPERATURE SENSORS

Different glasses suitable for temperature sensing in the fiber optic sensors were studied in this article. The phase changes for eight different glass materials were calculated and results were compared. Our results showed that extra dense flint glass is the most sensitive one, while pure silica results in the lowest phase change. In another study the effect of wavelength on the phase variatio...

متن کامل

Durability of Embedded Fibre Optic Sensors in Composites

...............................................................................................................III DISSERTATION....................................................................................................... VII DIVISION OF WORK BETWEEN AUTHORS .......................................................... IX INTRODUCTION..........................................................

متن کامل

Sensors 2001, 1, 13-17

The selectivity of measurements by means of affinity sensors in (quasi)equilibrium conditions and in non-equilibrium conditions was compared. The results show that the measurements in non-equilibrium conditions can reduce or even eliminate a relative contribution of interferents to a sensor signal.

متن کامل

Review of Chemical Sensors for In-Situ Monitoring of Contaminants

This report presents a review of sensors and technologies that are capable of detecting and monitoring volatile organic compounds. The scope of this review was limited to those sensors that have the potential to be used in geologic environments for long-term monitoring applications. Four general categories of sensor technologies were reviewed: (1) chromatography and spectrometry; (2) electroche...

متن کامل

Weight Measurements by Using Simple Optical-Fiber Sensors (RESEARCH NOTE)

The use of different optical-fiber sensors for weighing measurements is Abstract described. By using three different mechanical stressing mechanisms, the operation of the fiber-to-fiber transducer systems are tested and the results are presented. Parameters such as sensitivity, hysteresis, resolution, and dynamic range are measured. A comparison of the results has shown that the sensor system m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001