Automated pre-column derivatization of amines in biological samples with dansyl chloride and with or without post-column chemiluminescence formation by using TCPO-H2O2.

نویسندگان

  • C Molins-Legua
  • P Campíns-Falcó
  • A Sevillano-Cabeza
چکیده

On-line automation of two different liquid chromatographic procedures, a pre-column derivatization system and a pre- and post-column system, in order to generate chemiluminescence is reported. Dansyl chloride (Dns-Cl) was used as a pre-column reagent to form fluorophores and bis(2,4,6-trichlorophenyl) oxalate (TCPO) and hydrogen peroxide (H2O2) as a post-column reagent to generate chemiluminescence. This procedure is based on the employment of a primary column packed with C18 material inserted in a multi-dimensional assembly for sample clean-up and derivatization with Dns-Cl. The dansyl derivatives formed are transferred and separated in a LiChrospher 100 RP18 analytical column (125 x 4 mm id, 5 microns film thickness) using acetonitrile-imidazole buffer (pH 6.8) (70 + 30) as eluent. The separated derivatives were transferred to the detector for fluorescence detection or to the post-column system where the chemiluminescence response was generated by using TCPO-H2O2 and the products were detected by chemiluminescence. The procedure was optimised for amphetamine and related compounds. A comparison between the on-line pre-column and pre- and post-column systems was performed. The results show that the sensitivity of chemiluminescence detection can be higher than that of fluorescence detection. The recoveries obtained ranged from 98 +/- 8 up to 108 +/- 8% for amphetamine and methamphetamine, respectively. The accuracy and precision of these methods were evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of Biojenic Amines Using Dansyl Cloride Derivatization and Mixed Micellar Liquid Chromatography

Separation of some biogenic amines via RP-HPLC using mixed micellar mobile phase was investigated. The compounds were derivatized before hand by dansyl chloride as a chromophoric reagent. Appropriate conditions for separation, were determined by studying factors such as temperature, type and percentage of organic modifier, concentration of surfactants (SDS and Brij-35) and the pH of the mob...

متن کامل

Determination of Biologically Active Polyamines in Turkey Breast Meat by HPLC and Derivatization with Dansyl Chloride

BacBackground and Objectives: polyamines (putrecsine, spermidine and spermine) are widespread components, which can be found in most of the foods like meat, fruits, vegetables, cheese and wine. Studies show that reducing the level of polyamines in cells may help to slow down some cancer processes however, dietary polyamines may be required in wound healing, and for growth, maturation and regene...

متن کامل

Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

متن کامل

A Sensitive Liquid Chromatographic Method for the Analysis of Clarithromycin with Pre-Column Derivatization: Application to a Bioequivalence Study

Objective(s) A sensitive liquid chromatographic method for the analysis of clarithromycin- a macrolide antibiotic- in human serum, using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. Materials and Methods The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes...

متن کامل

Simultaneous derivatization and extraction of primary short-chain aliphatic amines using an ultrasonic-mixed water-ionic liquid two-phase system for liquid chromatography.

Here, we report on a procedure in which ultrasonic waves were used to mix a water-ionic liquid two-phase system to simultaneously derivatize amines with dansyl chloride and extract, and the resulting dansyl amines into an ionic liquid (IL) at room temperature within 15 min. The ILs used were room-temperature ionic liquids (RTILs), such as 1-alkyl-3-methylimidazolium hexafluorophosphate ([C(n)MI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 123 12  شماره 

صفحات  -

تاریخ انتشار 1998