3D Simulation of the Thermal Response Test in a U-tube Borehole Heat Exchanger

نویسنده

  • L. Schiavi
چکیده

Simulated Thermal Response Test data are analyzed in order to evaluate the effect of the tridimensionality model’s feature in determining the proper value of the soil thermal conductivity and borehole thermal resistance, necessary for the geothermal energy storage systems’ design in real conditions. The 3D system’s simulation during the Thermal Response Test is realized by adopting the finite element method implemented within the Comsol Multiphysics® environment. The comparison of the numerical results with the analytical solution of the Line Source Model problem, enables to discuss the capability of the Thermal Response Test with regards to the characterization of borehole energy storage systems in real conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation

Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...

متن کامل

An extended two-dimensional borehole heat exchanger model for simulation of short and medium timescale thermal response

Common approaches to the simulation of Borehole Heat Exchangers (BHEs) assume heat transfer in circulating fluid and grout to be in a quasi-steady state and ignore fluctuations in fluid temperature due to transport of the fluid around the U-tube loop. Such effects have been shown to have an impact on peak temperatures and hence operation of heat pumps systems when short time scales are consider...

متن کامل

Distributed Thermal Response Test on a U-pipe Borehole Heat Exchanger

In a Distributed Thermal Response Test (DTRT) the ground thermal conductivity and borehole thermal resistance are determined at many instances along the borehole. Here, such a test is carried out at a 260 m deep water filled energy well, equipped with a U-pipe borehole heat exchanger, containing an aqueous solution of ethanol as working fluid. Distributed temperature measurements are carried ou...

متن کامل

Improvement Of Thermal Conductivity Of Grout Mixture For Geothermal Heat Pump Systems

A vertical geothermal probe consists of two or four polyethylene tubes U-shaped, used for circulating the coolant between the heat pump and the ground. It is installed in a deep borehole and sealed in a special grout, a kind of liquid cement, used to seal the borehole, and avoid the presence of air bags between the probe and the ground. Moreover, the grout provides a heat transfer medium betwee...

متن کامل

Novel Wireless Sensor System for Dynamic Characterization of Borehole Heat Exchangers

The design and field test of a novel sensor system based in autonomous wireless sensors to measure the temperature of the heat transfer fluid along a borehole heat exchanger (BHE) is presented. The system, by means of two special valves, inserts and extracts miniaturized wireless sensors inside the pipes of the borehole, which are carried by the thermal fluid. Each sensor is embedded in a small...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009