[The runaway phenomenon: an unexplained pacemaker dysfunction].

نویسندگان

  • Javier Pindado
  • José A Cabrera
  • Jerónimo Farré
چکیده

Of pacemaker malfunctions,1 runaway pacemaker events are infrequent electronic complications that present at any time in the life of the pacemaker.2-4 Described between 2 days and 9 years after implantation, they are life-threatening emergencies that can go undetected if they appear intermittently.5,6 Recently, we attended a 96 year-old woman with a VVIR Medtronic Minix-ST pacemaker implanted in 1995 for symptomatic complete atrioventricular block. She was admitted to our coronary unit with dizziness and progressive dyspnea with blood pressure 130/60 mm Hg and bilateral crepitations in posterior plane. The electrocardiogram showed irregular pacemaker rhythm with 2 consecutive spikes generated at an interval of 960 ms, the second of which was followed by high frequency electric “interference” (3000 Hz). This interference initially accelerated and then decelerated until disappearing and we later registered normal, single pacemaker spikes at 4120 ms intervals (Figure A and B). The high frequency minispikes did not constitute artifacts as they were recorded systematically. Chest x-ray showed a pattern of acute pulmonary edema. The pacemaker problem persisted despite magnetic inhibition of the generator and use of a transitory stimulation electrode. The patient, treated with high dose inotropics and diuretics, finally died of multiorgan failure. In the 60s, incidence of this complication was 2%-4% with 30%-40% mortality.4 It presents in 2 forms: a) pacemaker-induced ventricular tachycardia; and b) extreme bradycardia due to impaired ventricular capture of rapid low amplitude sub-threshold pulses. Although bradycardia is better tolerated than tachycardia, mortality of both presentations does not differ significantly.3-5 Runaway pacemaker events should be considered when pacemaker stimulation frequency is above the established upper limit, excluding the possibility of pacemaker-mediated tachycardia. Runaway pacemaker events have been attributed to various causes: a) primary circuit failure; b) defects in the generator’s hermetic seal; c) circuit damage caused by the electric scalpel or radio-frequency ablation; and d) sterilization of the generator with heat.7 Recently, a runaway event in a patient implanted with a defibrillator was reported.8 The runaway phenomenon is refractory to defibrillation and antiarrhythmic agents as the problem is intrinsic to the pacemaker. Reprogramming the generator and over-stimulation with a transitory electrode have been used with poor results. The use of a magnet to inhibit the pacemaker may be inefficient as this only disables the pacemaker’s sensing function. Consequently, the only efficient treatment may be disconnecting the generator electrodes by cutting leads or reprogramming the system.9 LE T T E R S TO T H E ED I TO R

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Report of a Case of Pacemaker Depletion Presenting with Wide QRS Tachycardia Geniş QRS Taşikardi ile Başvuran Kalp Pilinin Tükenmesi: Runaway Pacemaker

Runaway pacemaker results from pacemaker malfunction and is characterized by sudden increases in the stimulus rate above the set upper rate limit of the pacemaker. Here we report the case of a patient with wide QRS complex tachycardia who was admitted to the emergency unit and diagnosed with runaway pacemaker.

متن کامل

Family process and structure, attachment style, and emotional intelligence in runaway girls

Introduction: The phenomenon of running away from home is taken into account as one of the highly sensitive and complicated issues in the field of social harms. According to a report released by the WHO, the annual rate of running away from home is more than 2.3 million. Thus, the purpose of the present study was to compare family structure and process, attachment style, and emotional intellige...

متن کامل

Muscle potentials simulating pacemaker malfunction.

Interference spikes were noted on the electrocardiogram of a patient with an implanted demand pacemaker. Runaway malfunction was suspected and the generator replaced. Subsequent investigation showec that the interference originated from fasciculation in the left leg caused by underlying neuromuscular disease. Skeletal muscle potentials can produce an electrocardiographic appearance closely rese...

متن کامل

Runaway pacemaker rhythm after 36 hours of electrical inactivity.

With the widespread application of permanent cardiac pacing, many publications have described bizarre manifestations of pacemaker failure including cases of life-threatening tachyarrhythmias induced by the pacemaker (Costeas et al., I965; Robinson et al., I965; Wisoff, Gabor, and Donoso, I965; Wallace, Abelmann, and Norman, 1970; Barold, I973). The purpose of this communication is to report the...

متن کامل

Ventricular ectopic rhythms due to rapid runaway pacemaker.

A patient initially had syncope due to a runaway pacemaker firing at an unusually rapid rate (30 impulses per second). The ventricular arrhythmia was characterized by numerous ectopic beats, with coupling intervals related to the length of the preceding cycle and runs of ventricular tachycardia with slight variations in the intervals between beats. This case demonstrates the clinical characteri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 58 9  شماره 

صفحات  -

تاریخ انتشار 2005