Development of the Spectral Deconvolution Analysis Tool (sdat) to Improve Counting Statistics and Detection Limits for Nuclear Explosion Radionuclide Measurements

نویسندگان

  • S. R. Biegalski
  • K. M. Foltz
  • D. A. Haas
چکیده

The Spectral Deconvolution Analysis Tool (SDAT) is being written to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT will utilize spectral deconvolution spectroscopy techniques to analyze both β−γ coincidence spectra for radioxenon isotopes and high-resolution High Purity Germanium (HPGe) spectra that are utilized for aerosol monitoring. Spectral deconvolution spectroscopy is an analysis method that utilizes the entire signal deposited in a gamma-ray detector rather than the small portion of the signal that is present in one gamma-ray peak. Counting statistics are improved by utilizing the entire detector response and the deconvolution algorithm directly handles interferences between radionuclides. This method shows promise to improve detection limits over classical gamma-ray spectroscopy analytical techniques. The Multiple Isotope Comparison Analysis (MICA) algorithm was developed previously to demonstrate the concept for this technique for β−γ coincidence spectra utilized for radioxenon analysis. These spectra are difficult to analyze by the classical peak analysis technique due to spectral interferences among the radioxenon isotopes as well as the interferences between radon progeny and the radioxenon isotopes. The deconvolution algorithm unravels the interferences and utilizes the complete signal from each radionuclide. While the MICA algorithm has demonstrated its utility for the analysis of β−γ coincidence spectra, additional developments are necessary before this technique reaches a point where it may be applied in an operational environment. SDAT will incorporate the complete functionality of the MICA algorithm, will add in spectral weighting functions to reduce the analytical residual, and will include the ability to analyze high-resolution HPGe spectra with the deconvolution method. A significant portion of this work will involve the development of calibration methods for both radioxenon and high-resolution HPGe systems. Proper calibrations of the detection systems are especially necessary for application of the spectral deconvolution spectroscopy algorithm. The detector response from each radionuclide of interest must be individually determined. The University of Texas TRIGA reactor will be utilized to irradiate a fission product generator for production of xenon isotopes for calibration. Fission products will also be generated for calibration and testing of the SDAT algorithm for HPGe spectra. Calibrations will be conducted through experimental measurements and will also be supported through Monte Carlo N-Particle Extended (MCNPX) modeling. 770 27th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of the structural and spectral properties for L,L-ethylenedicysteine diethylester (EC) and its complex with Technetium-99m radionuclide

The technetium-99m complex of the L,L-ethylenedicysteine diethylester (EC), of the brain imaging agent, was reported as a good choice for replacement of the renal nuclear medicines like OIH radiopharmaceutical. This present research work studies the structural, electronic and spectral properties of the EC compound and its complex with technetium-99m radionuclide from theoretical insight. All co...

متن کامل

CHARACTERIZATION AND PERFORMANCE EVALUATION OF AN HPXe DETECTOR FOR NUCLEAR EXPLOSION MONITORING APPLICATIONS

Expanding missions in nuclear explosion monitoring (NEM) and nuclear security have highlighted the need for high-resolution ambient-temperature gamma detectors that can provide radionuclide-specific monitoring under demanding field conditions. Recent improvements in high-pressure xenon (HPXe) detectors indicate that this technology has potential to provide rugged, large volume ambient temperatu...

متن کامل

Nonparametric Spectral-Spatial Anomaly Detection

Due to abundant spectral information contained in the hyperspectral images, they are suitable data for anomalous targets detection. The use of spatial features in addition to spectral ones can improve the anomaly detection performance. An anomaly detector, called nonparametric spectral-spatial detector (NSSD), is proposed in this work which utilizes the benefits of spatial features and local st...

متن کامل

Target Detection Improvements in Hyperspectral Images by Adjusting Band Weights and Identifying end-members in Feature Space Clusters

          Spectral target detection could be regarded as one of the strategic applications of hyperspectral data analysis. The presence of targets in an area smaller than a pixel’s ground coverage has led to the development of spectral un-mixing methods to detect these types of targets. Usually, in the spectral un-mixing algorithms, the similar weights have been assumed for spectral bands. Howe...

متن کامل

Development of 153Sm/177Lu-EDTMP as a possible therapeutic complex

Introduction:Targeted radionuclide therapy (TRT) has been demonstrated to be an effective therapeutic tool in patients with disseminated bone metastasis. TRT is generally performed with a single radionuclide. In this study we investigated the feasibility of combined TRT with a high-energy beta emitter (153Sm) and a low energy beta emitter (177Lu) in wistar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005