Age- and Sex-Dependency of Laser Speckle Flowgraphy Measurements of Optic Nerve Vessel Microcirculation

نویسندگان

  • Naoko Aizawa
  • Hiroshi Kunikata
  • Fumihiko Nitta
  • Yukihiro Shiga
  • Kazuko Omodaka
  • Satoru Tsuda
  • Toru Nakazawa
  • Louis R. Pasquale
چکیده

PURPOSE To investigate the relationship between various characteristics of a normal population and laser speckle flowgraphy (LSFG) measurements of mean blur rate (MBR) in the optic nerve head (ONH). METHODS A total of 189 eyes of 189 normal subjects (93 male, 96 female, mean age 45 ± 14 years old, age range: 20-72) without any history of hypertension, hyperlipidemia or diabetes were enrolled. ONH microcirculation was measured with LSFG and overall MBR (MA), vessel-area MBR (MV), and tissue-area MBR (MT) were derived from these measurements. The statistical association of these measurements with characteristics such as sex, age, intraocular pressure (IOP) and systolic blood pressure (SBP) was then determined. RESULTS There was a trend towards decreased IOP and MV and increased SBP with age (P = 0.002, P = 0.035, and P = 0.006, respectively). Furthermore, IOP, MV and SBP were correlated with age (r = -0.23, P = 0.011; r = -0.24, P < 0.001; and r = 0.30, P < 0.001, respectively). Separate multiple regression analyses of independent contributing factors revealed that sex and IOP contributed to MA (P < 0.001 and P = 0.002, respectively), sex, IOP, and age contributed to MV (P < 0.001, P = 0.003, and P = 0.024, respectively), while only IOP contributed to MT (P = 0.003). CONCLUSION In a normal population, MBR was affected by IOP in both the large vessel and capillary areas of the ONH, but not by SBP. MV was also affected by age and sex, while MT was stable independent of age or sex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of cerebral circulation during retrograde perfusion by laser speckle flowgraphy

Laser speckle flowgraphy (LSFG) is an ophthalmologic equipment that qualitatively detects the blood flow of the optic nerve head, which is known to be related with cerebral microcirculation. LSFG can also measure the mean blur rate, which quantitatively calculates the blood flow. We aimed to assess the utility of LSFG in the evaluation of cerebral perfusion during aortic surgery under hypotherm...

متن کامل

Correlation between structure/function and optic disc microcirculation in myopic glaucoma, measured with laser speckle flowgraphy

BACKGROUND It is difficult to identify glaucoma in myopic eyes because the configuration of the optic disc varies; yet it is important clinically. Here, we used laser speckle flowgraphy (LSFG) to measure mean blur rate (MBR), representing optic disc microcirculation, and assessed its ability to identify glaucoma in eyes with myopic optic discs. METHODS 129 eyes (normal disc: 21 eyes; myopic d...

متن کامل

Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting

When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigat...

متن کامل

Relationship of Ocular Microcirculation, Measured by Laser Speckle Flowgraphy, and Silent Brain Infarction in Primary Aldosteronism

PURPOSE Recent studies have shown that the risk of cerebro- and cardiovascular events (CVEs) is higher in patients with primary aldosteronism (PA) than in those with essential hypertension (EH), and that silent brain infarction (SBI) is a risk factor and predictor of CVEs. Here, we evaluated the relationship between findings from laser speckle flowgraphy (LSFG), a recently introduced non-invasi...

متن کامل

Reproducibility of Neonate Ocular Circulation Measurements Using Laser Speckle Flowgraphy

Measuring the ocular blood flow in neonates may clarify the relationships between eye diseases and ocular circulation abnormalities. However, no method for noninvasively measuring ocular circulation in neonates is established. We used laser speckle flowgraphy (LSFG) modified for neonates to measure their ocular circulation and investigated whether this method is reproducible. During their norma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016