Ablation for atrial fibrillation during mitral valve surgery: 1-year results through continuous subcutaneous monitoring.

نویسندگان

  • Alexandr Bogachev-Prokophiev
  • Sergey Zheleznev
  • Alexander Romanov
  • Evgeny Pokushalov
  • Alexey Pivkin
  • Giorgio Corbucci
  • Alexander Karaskov
چکیده

Continuous monitoring of cardiac rhythm may play an important role in measuring the true symptomatic/asymptomatic atrial fibrillation (AF) burden and improve the management of anti-arrhythmic and anti-thrombotic therapies. Forty-seven patients with mitral valve disease and longstanding persistent AF (LSPAF) underwent a left atrial maze procedure with bipolar radiofrequency and valve surgery. The follow-up data recorded by an implanted loop recorder were analysed after 3, 6 and 12 months. On discharge, 40 (85.1%) patients were in stable sinus rhythm, as documented by in-office electrocardiography (ECG), 4 (8.5%) were in pacemaker rhythm and 3 (6.4%) were in AF. One (2.1%) patient died after 7 months. On 12-month follow-up examination, 30 (65.2%) patients had an AF burden <0.5% and were classified as responders. Three (6.5%) of the 16 non-responders had atrial flutter and 13 (27.7%) had documented AF recurrences with an AF burden >0.5%. Two (4.3%) patients with AF recurrences were completely asymptomatic. Among the symptomatic events stored by the patients, only 27.6% was confirmed as genuine AF recurrences according to the concomitant ECG recorded by the implanted loop recorder. A concomitant bipolar maze procedure during mitral valve surgery is effective in treating AF, as proved by detailed 1-year continuous monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical ablation of atrial fibrillation with a novel bipolar radiofrequency device.

OBJECTIVE When used for epicardial ablation, unipolar devices do not predictably yield transmural scars. Bipolar radiofrequency proved highly effective on the animal model, but clinical experience is still initial. We describe acute electrophysiologic findings and follow-up results of epicardial ablation with a novel bipolar radiofrequency device. METHODS A bipolar ablator was used to perform...

متن کامل

[Comment on “Surgical ablation of atrial fibrillation during mitral-valve surgery”].

BACKGROUND Among patients undergoing mitral-valve surgery, 30 to 50% present with atrial fibrillation, which is associated with reduced survival and increased risk of stroke. Surgical ablation of atrial fibrillation has been widely adopted, but evidence regarding its safety and effectiveness is limited. METHODS We randomly assigned 260 patients with persistent or long-standing persistent atri...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Surgical treatment of atrial fibrillation using bipolar radiofrequency ablation in rheumatic mitral disease.

OBJECTIVE To analyze the effectiveness of surgical treatment of atrial fibrillation (AF) using bipolar radiofrequency ablation during mitral valve procedures of rheumatic etiology in heart surgery. METHODS We retrospectively reviewed medical registries of 53 patients submitted to atrial ablation with bipolar radiofrequency energy during mitral valve surgery. Thirty four (64%) patients were wo...

متن کامل

CTS Trials Network: Surgical ablation of atrial fibrillation during mitral valve surgery - many questions unanswered

A disease that is associated with stroke and mortality, atrial fibrillation (AF) complicates 30 to 50% of mitral valve disease patients admitted for surgery.(1) Since the introduction of the Cox maze III procedure in 1992 many efforts have been made to come up with modified lesion sets and/or energy sources to surgically treat AF. This lead to the recently published American Heart Association (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2012