Serum amyloid A protein monitoring for early prediction of kidney allograft rejection.

نویسندگان

  • M T Casl
  • G Bulatović
  • P Orlić
  • M Sabljar-Matovinović
چکیده

Dr. Martin T. Časl, Nova Ves 36, 41000 Zagreb (Croatia) Dear Sir, Early recognition of allograft rejection remains a major problem in clinical renal transplantation. Monitoring of inflammatory responses in the postgrafting period [1-3] provides valuable information on the rejection process. Although some 30 plasma proteins increase in concentration during inflammation, only two of them are suitable markers of acute-phase response: serum amyloid A protein (SAA) and C-reactive protein (CRP) [4-6]. Both are quick to respond and both increase substantially in severe inflammation, SAA being the more sensitive parameter [4, 6-8]. Routine assays for SAA were not available until recently, mainly due to the difficulty in producing useful antisera against human SAA. A new micro-ELISA test [9] with commercially available sequence-specific antibody obtained from Ti-noLab Co., Zagreb, Croatia [10] now enables one to measure SAA quickly and routinely. We used this micro-ELISA assay for everyday monitoring of SAA in 17 patients (4 females and 13 males) with kidney allografts in order to facilitate an early diagnosis of rejection. Altogether 43 SAA peaks were observed and 19 of them were caused by allograft rejections. The results are presented in figure 1. During the first 3 of 4 days, the initial SAA peaks (caused by surgical trauma) 400-, a

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum amyloid A levels in human renal allograft rejection.

Serum amyloid A (SAA) levels were studied in 35 recipients of cadaveric renal transplants. Marked SAA elevations were seen during all acute allograft rejection episodes. The mean peak SAA level in well-documented rejections was 446 mg/l (median 415 mg/l, range 132-1040 mg/l; controls less than 1 mg/l). Rejections in patients receiving cyclosporin-A alone as post-transplantation immunosuppressiv...

متن کامل

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

The Predictive Value of HLA-DR Matching and Cytokine Gene Polymorphisms in Renal Allograft Acute Rejection: A Living-unrelated Donor (LURD) Study

Background: In addition to Human Leukocyte Antigens (HLA) compatibility, gene polymorphisms in cytokines might also be important in the quality of allogeneic immune response. Objective: To evaluate the influence of HLA-DR matching and a number of cytokine gene polymorphisms on acute rejection after living-unrelated donor (LURD) kidney transplantation. Methods: A total of 42 renal transplants pe...

متن کامل

Measurement of serum amyloid A protein concentrations

Serum amyloid A protein concentrations were monitored in 10 renal transplant recipients who required dialysis after transplantation because of an initially non-functioning graft. Fifteen rejection episodes were identified by repeated fine needle aspiration biopsies of the grafts. All rejections were characterised by pronounced increases in serum amyloid A concentrations, the mean peak value bei...

متن کامل

Serum amyloid A protein is a clinically useful indicator of acute renal allograft rejection.

BACKGROUND Early diagnosis of acute rejection after renal transplantation is important. There is evidence that measurement of the acute phase proteins, C-reactive protein (CRP) and serum amyloid A protein (SAA) is helpful. METHODS In 64 consecutive patients, CRP was measured in a routine clinical system (Technicon RA1000, Bayer) and SAA in a new sensitive automated immunoassay on the Abbott I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephron

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 1995