Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.
نویسندگان
چکیده
OBJECTIVE To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. DESIGN Validation study. ANIMALS 16 healthy adult Hispaniolan Amazon parrots. PROCEDURES Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. RESULTS There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.
منابع مشابه
Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).
OBJECTIVE To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). ANIMALS 20 healthy adult Hispaniolan Amazon parrots. PROCEDURES A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) fro...
متن کاملEffect of anesthesia, positioning, time, and feeding on the proventriculus: keel ratio of clinically healthy parrots.
Healthy, adult Hispaniolan Amazon parrots (Amazona ventralis) were imaged on three occasions to determine the effects of anesthesia, patient rotation, feeding, and short/long-term temporal factors on the proventriculus:keel ratio. Increasing rotation up to 15 degrees from right lateral resulted in increased inability to measure the proventriculus in up to 44% of birds, meaning that the proventr...
متن کاملComparison of hematologic values in blood samples with lithium heparin or dipotassium ethylenediaminetetraacetic acid anticoagulants in Hispaniolan Amazon parrots (Amazona ventralis).
Blood samples were collected from 20 Hispaniolan Amazon parrots (Amazona ventralis) and were divided into tubes that contained dipotassium ethylenediaminetetraacetic acid (K2EDTA) and lithium heparin. Complete blood cell counts were determined in each sample within 2 hours of collection. The level of agreement in results was moderate for plasma protein, packed cell volume (PCV), and leukocyte, ...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملEvaluation of Doppler Ultrasonic and Oscillometric Methods of Indirect Blood Pressure Measurement in Cats
Reliability of 804 indirect measurements of systemic arterial blood pressure (BP) was assessed in 13 cats by comparing results obtained indirectly by oscillometry (BPo) and Doppler ultrasonography (BPud) with those obtained simultaneously by a reference method, direct radiotelemetry (BPrt). The reliability varied considerably among sites of cuff placement and method of indirect measurement in c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Veterinary Medical Association
دوره 233 10 شماره
صفحات -
تاریخ انتشار 2008