On the use of the "look-locker correction" for calculating T1 values from MOLLI

نویسنده

  • Glenn S Slavin
چکیده

Background MOLLI [1] uses interleaved Look-Locker (LL) blocks for cardiac T1 mapping. Data is fit to the equation A-Bexp (-TI/T1*) to yield an “apparent” T1 (T1*), which is dependent on both the true T1 and imaging parameters. To estimate true T1, a “LL correction” T1est=(B/A-1) T1* [Eq. 1] has been proposed [1,2]. Although this correction can provide reasonable estimates of true T1, we are not aware of a rigorous justification for its use. The purpose of this work was to investigate the applicability of this correction for MOLLI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical application of MOLLI T1* for extracellular volume calculation in healthy volunteers and aortic stenosis

Background The calculation of the extracellular volume fraction (ECV) requires accurate quantification of myocardial and blood pool T1. Some Modified look locker inversion recovery (MOLLI) sequences provide a T1 and T1* output. T1* does not use a look locker correction, and so it is theoretically a more accurate estimation of true T1 blood T1 because fresh spins are flowing into the imaging pla...

متن کامل

How Accurate Is MOLLI T1 Mapping In Vivo? Validation by Spin Echo Methods

T1 mapping is a promising quantitative tool for assessing diffuse cardiomyopathies. The purpose of this study is to quantify in vivo accuracy of the Modified Look-Locker Inversion Recovery (MOLLI) cardiac T1 mapping sequence against the spin echo gold standard, which has not been done previously. T1 accuracy of MOLLI was determined by comparing with the gold standard inversion recovery spin ech...

متن کامل

Myocardial T1 measurement: comparison of modified Look-Locker inversion recovery (MOLLI) and TI scout in the Multi-ethnic Study of Atherosclerosis (MESA)

Different cardiac MR acquisition sequences have been used to obtain myocardial T1 values. Among which available techniques, MOdified Look-Locker Inversionrecovery (MOLLI) and inversion-recovery TrueFisp (TI scout) sequences are widely used in research and clinical settings. We compared myocardial T1 values derived from both MOLLI and TI scout techniques in the post gadolinium delayed enhancemen...

متن کامل

Influence of fat on liver T 1 measurements using modified Look–Locker inversion recovery (MOLLI) methods at 3T

PURPOSE To characterize the effect of fat on modified Look-Locker inversion recovery (MOLLI) T1 maps of the liver. The balanced steady-state free precession (bSSFP) sequence causes water and fat signals to have opposite phase when repetition time (TR) = 2.3 msec at 3T. In voxels that contain both fat and water, the MOLLI T1 measurement is influenced by the choice of TR. MATERIALS AND METHODS ...

متن کامل

True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI

Background SMART1Map is a new single-point technique for cardiac T1 mapping [1]. Unlike Look-Locker approaches, such as MOLLI, which yield an “apparent” T1 (T1*), SMART1Map directly measures true T1. Because T1* is a function of imaging parameters, it is always shorter than T1, and correction methods are required to obtain the true T1. This work compared the accuracy of SMART1Map with MOLLI in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014