Optimum shielding structure for the wall of medical LINAC facility

نویسندگان

  • Kazuaki Kosako
  • Koji Oishi
  • Takashi Nakamura
  • Yoshiaki Kiyanagi
چکیده

When considering the space limit of high energy LINAC facility in a hospital, the design of shielding wall is strongly required to optimize the wall thickness. Shielding wall usually consists of concrete, and iron plate is sometimes added in concrete to decrease the wall thickness. We investigated the optimum design of the shielding wall in medical LINAC facility by simulation. The calculations were carried out by the three-dimensional Monte Carlo code, MCNP5. The electron energy used in this investigation is 28 MeV. In the calculations, the wall thickness was fixed to 100 cm from the viewpoint of durability and reliability and the cost to build the shielding wall. In the shielding wall consisting of iron and concrete, the suitable configuration was found to have 40-50 cm-thick iron at the front side. But it was insufficient to achieve the required attenuation rates of 2 x 10 and 5 x 10 for effective neutron and photon doses, respectively. We further searched the optimum combination of shielding materials to get the most efficient attenuation profile and finally obtained the optimum arrangement of 100 cm thick shielding wall having the multi-layered structure of iron 40 cm, polyethylene 10 cm, iron 20 cm, lead 10 cm, polyethylene 10 cm, and concrete 10 cm in this order. In order to investigate the shielding capability of this multi-layered shielding wall, the neutron and photon dose rates were measured using the 45 MeV electron linear accelerator of Hokkaido University to verify the MCNP5 calculated results. The MCNP5 calculation was found to give good accuracy within 30% for the multi-layered shielding structure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shielding evaluation and acceptance testing of a prefabricated, modular, temporary radiation therapy treatment facility

We have recently commissioned a temporary radiation therapy facility that is novel in two aspects: it was constructed using modular components, and the LINAC was installed in one of the modular sections before it was lifted into position. Additional steel and granular fill was added to the modular sections on-site during construction. The building will be disassembled and removed when no longer...

متن کامل

Treatment vault shielding for a flattening filter-free medical linear accelerator.

The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...

متن کامل

Shielding studies on a total-body neutron activation facility

Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

Magnetic decoupling of the linac in a low field biplanar linac-MR system.

PURPOSE The integration of a low field biplanar magnetic resonance (MR) imager and linear accelerator (linac) causes magnetic interference at the linac due to the MR fringe fields. In order to eliminate this interference, passive and active magnetic shielding designs are investigated. METHODS The optimized design of passive magnetic shielding was performed using the finite element method. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013