Improved correlation to quantitative DCE-MRI pharmacokinetic parameters using a modified initial area under the uptake curve (mIAUC) approach.

نویسنده

  • Hai-Ling Margaret Cheng
چکیده

PURPOSE To propose a modified initial area under the uptake curve (mIAUC) dynamic contrast-enhanced (DCE)-MRI approach to achieve better distinction of underlying physiology. MATERIALS AND METHODS The mIAUC is formulated on common characteristics of tissue contrast uptake curves observed over a wide range of physiological conditions. The new metrics, IAUC(Ktrans) and IAUC(ve), are related to the transfer constant (K(trans)) and interstitial volume (v(e)), respectively. Tissue uptake curves were simulated over a range of physiological values and analyzed using the proposed mIAUC, conventional IAUC, and Tofts' pharmacokinetic model. RESULTS IAUC(Ktrans) and IAUC(ve) are highly correlated to the true K(trans) and v(e) (rho = 0.97 and 0.95, respectively), approaching the performance of Tofts' model based on a 1.5-s sampled arterial input function (AIF) (rho = 0.98 and 0.98) under noise conditions typical in DCE-MRI experiments. Lower correlations were obtained with conventional IAUC(60) and IAUC(120) (rho = 0.82 and 0.61) and Tofts' parameters fitted using a biexponential AIF (rho = 0.81 and 0.90). CONCLUSION The proposed mIAUC approach retains advantages associated with nonmodel based methods (robust to noise and model fit failure, obviates need for an AIF) while providing better distinction of underlying physiological parameters. It can be a valuable alternative to pharmacokinetic modelling in the analysis of DCE-MRI data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vascular responses to radiotherapy and androgen-deprivation therapy in experimental prostate cancer

BACKGROUND Radiotherapy (RT) and androgen-deprivation therapy (ADT) are standard treatments for advanced prostate cancer (PC). Tumor vascularization is recognized as an important physiological feature likely to impact on both RT and ADT response, and this study therefore aimed to characterize the vascular responses to RT and ADT in experimental PC. METHODS Using mice implanted with CWR22 PC x...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Can Dynamic Contrast-Enhanced MRI (DCE-MRI) and Diffusion-Weighted MRI (DW-MRI) Evaluate Inflammation Disease

The aim of the study was to investigate diagnosis efficacy of dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted MRI (DW-MRI) in Crohn's disease (CD). To find out the correlations between functional MRI parameters including K, Kep, Ve, Vp, and apparent diffusion coefficient (ADC) with a serologic biomarker. The relationships between pharmacokinetic parameters and ADC were also studi...

متن کامل

Quantitative pharmacokinetic analysis of prostate cancer DCE-MRI at 3T: comparison of two arterial input functions on cancer detection with digitized whole mount histopathological validation.

Accurate pharmacokinetic (PK) modeling of dynamic contrast enhanced MRI (DCE-MRI) in prostate cancer (PCa) requires knowledge of the concentration time course of the contrast agent in the feeding vasculature, the so-called arterial input function (AIF). The purpose of this study was to compare AIF choice in differentiating peripheral zone PCa from non-neoplastic prostatic tissue (NNPT), using P...

متن کامل

Quantification of abdominal aortic aneurysm wall enhancement with dynamic contrast-enhanced MRI: feasibility, reproducibility, and initial experience.

PURPOSE To investigate the feasibility and reproducibility of dynamic contrast-enhanced MRI (DCE-MRI) to quantify abdominal aortic aneurysm (AAA) vessel wall enhancement dynamics which may reflect the amount of wall microvasculature. AAA vessel wall microvasculature has been linked with aneurysm progression and rupture. MATERIALS AND METHODS Thirty patients with AAA underwent DCE-MRI at 1.5 T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2009