Evaluation of automated large-scale screening tests for syphilis.

نویسندگان

  • D E Macfarlane
  • K Hare
  • T F Elias-Jones
چکیده

Two methods of performing serological screening tests for syphilis are compared. One consisted of the Venereal Diseases Reference Laboratory (VDRL) slide test, the cardiolipin Wassermann reaction (CWR), and the Reiter protein complement fixation test (RPCFT) performed manually; the other was a fully automated system using two Technicon AutoAnalyzers (AAII), one for the automated reagin test (ART) and the other for automated complement fixation tests. The absorbed fluorescent treponemal antibody test (FTA-ABS) was used as a final arbiter in all cases found to be seropositive by either method. A pooled antigen consisting of a mixture of cardiolipin and Reiter protein was used for the automated complement fixation test, thus increasing the scope and capacity of the system. The AutoAnalyzer was shown to be capable of performing 400 cardiolipin and Reiter complement fixation tests and 700 automated reagin tests in an 8-hour day. Modification of the complement fixation test method to take advantage of the highly sensitive colorimeter resulted in a significant increase in sensitivity and a corresponding saving in reagents. Of the 7843 sera tested, 258 gave a positive result in one or more of the screening tests. The automated test detected many more Reiter positive sera (127) than the manual test (83). Conversely, fewer CWR positive sera were detected by the automated test (60) than by the manual test (82). There was little difference between the number of positive sera detected by the ART (73) and the VDRL slide test (71). In 19 instances the automated tests detected positive sera which registered as completely negative in the manual tests, and four seropositive cases which the automated tests had failed to detect were detected by the manual tests, and four seropositive cases which the automated tests had failed to detect were detected by the manual tests. It was concluded that a combination of the ART and automated Reiter protein complement fixation test (ARPCFT) would be ideal for use in a large-scale screening programme for the detection of syphilis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screening tests for syphilis. A comparison of the Treponema pallidum haemagglutination assay with two automated serological tests.

Two Treponema pallidum haemagglutination assay (TPHA) tests (Wellcome and Fuzizoki) were compared with the automated reagin test and the automated Reiter protein complement-fixation test in a routine screening system. The Wellcome TPHA was shown to lack sensitivity, and it is recommended that it should be used at a lower screening dilution. The Fuzizoki TPHA recorded a significant number of fal...

متن کامل

Integrating syphilis screening in a large-scale HIV prevention program for key populations: the Avahan experience from India.

INTRODUCTION Documented experiences from India on the implementation of syphilis screening in large-scale HIV prevention programs for "key populations at higher risk" (KPs) are limited. Avahan is a large-scale HIV prevention program providing services to more than 300,000 KPs in six high HIV prevalence states of India since 2004. Avahan clinics provide a sexually transmitted infection service p...

متن کامل

Enzyme linked immunosorbent assays with Treponema pallidum or axial filament of T phagedenis biotype Reiter as antigen: evaluation as screening tests for syphilis.

Enzyme linked immunosorbent assays with an ultrasonicate of Treponema pallidum (TP-ELISA) or axial filament of Treponema phagedenis biotype Reiter (AF-ELISA) were developed to detect treponemal antibody. TP-ELISA and AF-ELISA were compared with the T pallidum haemagglutination assay (TPHA), the fluorescent treponemal antibody-absorbed (FTA-ABS) test, and the Venereal Disease Research Laboratory...

متن کامل

Form II HRP Research Proposal: Project details Utility evaluation of Point-of-Care Tests in Non-Clinical Settings for the Screening of HIV and Syphilis in Men Who Have Sex with Men 1. Project summary

Serologic tests are the diagnostic tests of choice for HIV and syphilis. There are two types of serological tests (treponemal and non-treponemal tests) for laboratory diagnosis of syphilis. Traditionally, one non-treponemal assay is used for screening and a treponemal assay is used for confirmation for syphilis. For diagnosis of HIV EIAs are used for screening and Western blot for confirmation ...

متن کامل

Evaluation of a fully automated treponemal test and comparison with conventional VDRL and FTA-ABS tests.

We evaluated analytic performances of an automated treponemal test and compared this test with the Venereal Disease Research Laboratory test (VDRL) and fluorescent treponemal antibody absorption test (FTA-ABS). Precision performance of the Architect Syphilis TP assay (TP; Abbott Japan, Tokyo, Japan) was assessed, and 150 serum samples were assayed with the TP before and after heat inactivation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 1976