Ventilation and Radon Dynamics in Maine Seasonal Snowcover
نویسنده
چکیده
Radon concentrations and fluxes were measured for seasonal snowpack on Baldpate Mtn. in Newry, Maine during the winter of 2004. A solar radiation and temperature logging system was developed to monitor the snowpack during the radon measurements. Radon ground flux measurements were performed using a RAD-7 alpha spectrometer and ranged from 0.49 to 0.64 pCi m s for two different locations. Radon concentration as a function of time was measured inside the snowpack using a Honeywell A9000 radon monitor and showed average radon concentrations ranging from 1 to 12 pCi L, though maximum concentrations of over 80 pCi L were observed. Wind-driven and natural circulation airflows within the snowpack were shown to be the major factors controlling radon dynamics. Dilution rates of 1.25 pCi L h were correlated with windspeeds of 9 m s, while radon concentration rates of 0.8 pCi L h were observed during periods of calm. Comparison of long term track-etch cup measurements with radon diffusion theory showed that radon within the snowpack rarely exists in steady state distribution due to the ventilation effects of wind and natural circulation air flows. This study shows that radon dynamics can be used to measure air flows inside the snowpack.
منابع مشابه
The role of natural ventilation on reducing indoor radon concentration
Due to the increasing of closed ventilation systems used in buildings, the risk of indoor radon is increased day by day. In this study, we selected two sample rooms to calculate the radon emission coefficient from different levels, radon concentration measured when the natural ventilation was completely closed and compared with the analytical results. The results clearly show the difference in ...
متن کاملYukon River streamflow response to seasonal snow cover changes
We used remotely sensed weekly snow water equivalent (SWE) and snow cover extent (SCE) data to investigate streamflow response to seasonal snowcover change over the Yukon watershed. We quantified the seasonal cycles and variations of snowcover (both SWE and SCE) and river streamflow, and identified a clear correspondence of river discharge to seasonal snowcover change. We also examined and comp...
متن کاملSeasonal variation of radon, thoron and their progeny levels in dwellings of Haryana and Western Uttar Pradesh
Background: Radon and thoron are invisible, odorless, heavy and radioactive gases which are ubiquitously present in dwellings and in the environment. In the present work, seasonal variation of indoor radon, thoron and their progeny concentrations has been studied in the dwellings of industrially polluted cities in District Faridabad, Haryana and District Mathura in Uttar Pradesh. Materials and ...
متن کاملSimulation of Ventilation Effects on Indoor Radon in a Detached House
CFD is widely used in indoor air quality, air flow pattern, indoor pollutant distribution and thermal comfort as a cost effective and powerful tool and it can be used to predict, estimate and visualize the indoor radon level. . The intention of this article is to use computational fluid dynamics (CFD), as a standalone tool to simulate indoor radon distribution and ventilation effects. This tech...
متن کاملExposure of school children to alpha particles
Background: A substantial part of the public’s natural radiation dose is due to the inhalation of radon gas. Most of the exposure occurs indoors where the airborne concentration of radon and its decay products is usually higher than outdoors. Materials and Methods: Radon activity concentration has been measured twice in 50 classrooms in 5 levels (10 each) during summer and winter using solid-st...
متن کامل