Calculating bone-lead measurement variance.
نویسنده
چکیده
The technique of (109)Cd-based X-ray fluorescence (XRF) measurements of lead in bone is well established. A paper by some XRF researchers [Gordon CL, et al. The Reproducibility of (109)Cd-based X-ray Fluorescence Measurements of Bone Lead. Environ Health Perspect 102:690-694 (1994)] presented the currently practiced method for calculating the variance of an in vivo measurement once a calibration line has been established. This paper corrects typographical errors in the method published by those authors; presents a crude estimate of the measurement error that can be acquired without computational peak fitting programs; and draws attention to the measurement error attributable to covariance, an important feature in the construct of the currently accepted method that is flawed under certain circumstances.
منابع مشابه
Calculating the uncertainty in lead concentration for in vivo bone lead x-ray fluorescence.
A revised mathematical treatment of the calibration line intercept has been published for in vivo bone lead measurements using 109Cd-based K-shell x-ray fluorescence. The revised calibration line treatment prompts changes, presented herein, to the method for calculating the measurement uncertainty.
متن کاملValidation of K-XRF bone lead measurement in young adults.
K-X-ray fluorescence (K-XRF) is a useful tool for assessing environmental exposure to lead in occupationally exposed individuals and older adults. This study explores the possibility of using this technique on young adults with low environmental lead exposure. Twenty-three college students, aged 18-21 years, were recruited for 2 hr of bone lead measurement. Bone lead measurements were taken fro...
متن کاملIntra- and Inter-Observer Reproducibility of Ultrasound Measurements of Pelvic Inlet Diameter in Pregnant Women
Objectives: To determine intraand inter-observer reproducibility of the ultrasound measurement of pelvic inlet in the first trimester of pregnancy. Methods: Transabdominal pelvic ultrasound was performed to measure the pelvic inlet anteroposterior diameter using a 2D probe in twelve Chinese women having a singleton pregnancy. Scans were performed in the first trimester by three sonographers. Th...
متن کاملThe use of K X-ray fluorescence for measuring lead burden in epidemiological studies: high and low lead burdens and measurement uncertainty.
X-ray fluorescence (XRF), a rapid, noninvasive, low-radiation-dose method of measuring bone lead content, has emerged as a promising tool for providing an integrated estimate of low-level lead accumulation in epidemiological studies. Our group has settled on an XRF instrument that utilizes K X-rays (K-XRF) and normalizes the measurement to bone calcium. The unit of measurement provided is in mi...
متن کاملPredictors of dimercaptosuccinic acid chelatable lead and tibial lead in former organolead manufacturing workers.
OBJECTIVES To identify predictors of tibial and dimercaptosuccinic acid (DMSA) chelatable lead in 543 organolead manufacturing workers with past exposure to organic and inorganic lead. METHODS In this cross sectional study, tibial lead (by 109Cd K-shell x ray fluorescence), DMSA chelatable lead (4 hour urinary lead excretion after oral administration of 10 mg/kg), and several exposure measure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental Health Perspectives
دوره 108 شماره
صفحات -
تاریخ انتشار 2000