Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: a pilot study.

نویسندگان

  • Alessia Gimelli
  • Matteo Bottai
  • Assuero Giorgetti
  • Dario Genovesi
  • Annette Kusch
  • Andrea Ripoli
  • Paolo Marzullo
چکیده

BACKGROUND A novel technology has been developed for ultrafast (UF) single-photon emission CT (SPECT) myocardial perfusion imaging by using a pinhole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coronary artery disease. METHODS AND RESULTS A total of 34 patients underwent single-day (99m)Tc-tetrofosmin stress/rest myocardial perfusion imaging. UF-SPECT was performed 10 minutes before S-SPECT. Images were qualitatively analyzed, and the summed stress score and summed rest score were calculated. The segmental tracer uptake value (percentage of maximum myocardial uptake) also was quantified for both UF- and S-SPECT. When only 29 of 34 patients with significant coronary lesions were analyzed, the summed stress score was 10.1±4.4 versus 6.4±2.9, respectively, for UF- and S-SPECT (P=0.002). Qualitative and quantitative per-patient analysis showed similar results in detection of coronary artery disease for UF- and S-SPECT. In contrast, per-vessel analysis demonstrated higher regional sensitivity of UF- versus S-SPECT. UF-SPECT showed higher sensitivity in detecting multivessel disease (P=0.003) versus S-SPECT. CONCLUSIONS This pilot study confirms that UF-SPECT provides high-quality fast myocardial perfusion imaging and suggests that it may allow a more-accurate evaluation of both extent and severity of myocardial ischemia in patients with coronary artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison Between Ultrafast and Standard SPECT in Patients with Coronary Artery Disease: A Pilot Study

Background A novel technology has been developed for ultrafast (UF) singlephoton emission computed tomography (SPECT) myocardial perfusion imaging by employing a pin-hole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coro...

متن کامل

Systemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan

Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Functionally relevant coronary artery disease: comparison of 64-section CT angiography with myocardial perfusion SPECT.

PURPOSE To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS All patients gave written informed co...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 2011