Biological Calibration for Web-Based Hearing Tests: Evaluation of the Methods

نویسندگان

  • De Wet Swanepoel
  • Ian Brooks
  • Marcin Masalski
  • Tomasz Grysiński
  • Tomasz Kręcicki
چکیده

BACKGROUND Online hearing tests conducted in home settings on a personal computer (PC) require prior calibration. Biological calibration consists of approximating the reference sound level via the hearing threshold of a person with normal hearing. OBJECTIVE The objective of this study was to identify the error of the proposed methods of biological calibration, their duration, and the subjective difficulty in conducting these tests via PC. METHODS Seven methods have been proposed for measuring the calibration coefficients. All measurements were performed in reference to the hearing threshold of a normal-hearing person. Three methods were proposed for determining the reference sound level on the basis of these calibration coefficients. Methods were compared for the estimated error, duration, and difficulty of the calibration. Web-based self-assessed measurements of the calibration coefficients were carried out in 3 series: (1) at a otolaryngology clinic, (2) at the participant's home, and (3) again at the clinic. Additionally, in series 1 and 3, pure-tone audiometry was conducted and series 3 was followed by an offline questionnaire concerning the difficulty of the calibration. Participants were recruited offline from coworkers of the Department and Clinic of Otolaryngology, Wroclaw Medical University, Poland. RESULTS All 25 participants, aged 22-35 years (median 27) completed all tests and filled in the questionnaire. The smallest standard deviation of the calibration coefficient in the test-retest measurement was obtained at the level of 3.87 dB (95% CI 3.52-4.29) for the modulated signal presented in accordance with the rules of Bekesy's audiometry. The method is characterized by moderate duration time and a relatively simple procedure. The simplest and shortest method was the method of self-adjustment of the sound volume to the barely audible level. In the test-retest measurement, the deviation of this method equaled 4.97 dB (95% CI 4.53-5.51). Among methods determining the reference sound level, the levels determined independently for each frequency revealed the smallest error. The estimated standard deviations of the difference in the hearing threshold between the examination conducted on a biologically calibrated PC and pure-tone audiometry varied from 7.27 dB (95% CI 6.71-7.93) to 10.38 dB (95% CI 9.11-12.03), depending on the calibration method. CONCLUSIONS In this study, an analysis of biological calibration was performed and the presented results included calibration error, calibration time, and calibration difficulty. These values determine potential applications of Web-based hearing tests conducted in home settings and are decisive factors when selecting the calibration method. If there are no substantial time limitations, it is advisable to use Bekesy method and determine the reference sound level independently at each frequency because this approach is characterized by the lowest error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis

BACKGROUND Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. OBJECTIVE The aim of this research was to determine the measurement error of the hearing threshold determined in the way described above and to identify and analyze factors in...

متن کامل

AHP Techniques for Trust Evaluation in Semantic Web

The increasing reliance on information gathered from the web and other internet technologies raise the issue of trust. Through the development of semantic Web, One major difficulty is that, by its very nature, the semantic web is a large, uncensored system to which anyone may contribute. This raises the question of how much credence to give each resource. Each user knows the trustworthiness of ...

متن کامل

AHP Techniques for Trust Evaluation in Semantic Web

The increasing reliance on information gathered from the web and other internet technologies raise the issue of trust. Through the development of semantic Web, One major difficulty is that, by its very nature, the semantic web is a large, uncensored system to which anyone may contribute. This raises the question of how much credence to give each resource. Each user knows the trustworthiness of ...

متن کامل

Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran

Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...

متن کامل

Effects of Exposure to Impact Noise on the Hearing of Armed Forces and Evaluation of the Methods to Control and Decrease its Consequences: A Review Study

Background and Aim: Exposure to impact noise (short-term, high intensity) higher than permitted levels results in injury to the auditory system. Armed forces are one of the occupational groups exposed to these types of noises resulting from gunshots. In this study, relevant articles and research on the adverse effects of impact noise, hearing loss, and tinnitus in armed forces and effective con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014