Only carbon dioxide absorbents free of both NaOH and KOH do not generate compound A during in vitro closed-system sevoflurane: evaluation of five absorbents.

نویسندگان

  • L F Versichelen
  • M P Bouche
  • G Rolly
  • J F Van Bocxlaer
  • M M Struys
  • A P De Leenheer
  • E P Mortier
چکیده

BACKGROUND Insufficient data exist on the production of compound A during closed-system sevoflurane administration with newer carbon dioxide absorbents. METHODS A modified PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow at the top of the bellow approximately/= 160 ml/min CO2; outflow at the Y piece of the lung model approximately/= 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure of approximately 40 mmHg. Various fresh carbon dioxide absorbents were used: Sodasorb (n = 6), Sofnolime (n = 6), and potassium hydroxide (KOH)-free Sodasorb (n = 7), Amsorb (n = 7), and lithium hydroxide (n = 7). After baseline analysis, liquid sevoflurane was injected into the circuit by syringe pump to obtain 2.1% end-tidal concentration for 240 min. At baseline and at regular intervals thereafter, end-tidal carbon dioxide partial pressure, end-tidal sevoflurane concentration, and canister inflow (T degrees(in)) and canister outflow (T degrees(out)) temperatures were measured. To measure compound Ainsp concentration in the inspired gas of the breathing circuit, 2-ml gas samples were taken and analyzed by capillary gas chromatography plus mass spectrometry. RESULTS The median (minimum-maximum) highest compound Ainsp concentrations over the entire period were, in decreasing order: 38.3 (28.4-44.2)* (Sofnolime), 30.1 (23.9-43.7) (KOH-free Sodasorb), 23.3 (20.0-29.2) (Sodasorb), 1.6 (1.3-2.1)* (lithium hydroxide), and 1.3 (1.1-1.8)* (Amsorb) parts per million (*P < 0.01 vs. Sodasorb). After reaching their peak concentration, a decrease for Sofnolime, KOH-free Sodasorb, and Sodasorb until 240 min was found. The median (minimum-maximum) highest values for T degrees(out) were 39 (38-40), 40 (39-42), 41 (40-42), 46 (44-48)*, and 39 (38-41) degrees C (*P < 0.01 vs. Sodasorb), respectively. CONCLUSIONS With KOH-free (but sodium hydroxide [NaOH]-containing) soda limes even higher compound A concentrations are recorded than with standard Sodasorb. Only by eliminating KOH as well as NaOH from the absorbent (Amsorb and lithium hydroxide) is no compound A produced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the renal safety between carbon dioxide absorbent products under sevoflurane anesthesia: a pilot study

BACKGROUND The chemical reaction of carbon dioxide absorbent and sevoflurane is known to produce compound A. However, carbon dioxide absorbents are not controlled by the Food and Drug Administration, but are treated as industrial products in some nations. Moreover, carbon dioxide absorbents differ in their capacities to produce compound A, because their chemical compositions differ. In this stu...

متن کامل

Carbon dioxide absorbents containing potassium hydroxide produce much larger concentrations of compound A from sevoflurane in clinical practice.

UNLABELLED We investigated the concentrations of degraded sevoflurane Compound A during low-flow anesthesia with four carbon dioxide (CO(2)) absorbents. The concentrations of Compound A, obtained from the inspiratory limb of the circle system, were measured by using a gas chromatograph. In the groups administered 2 L/min fresh gas flow with 1% sevoflurane, when the conventional CO(2) absorbents...

متن کامل

Lack of degradation of sevoflurane by a new carbon dioxide absorbent in humans.

BACKGROUND Potent inhaled anesthetics degrade in the presence of the strong bases (sodium hydroxide or potassium hydroxide) in carbon dioxide (CO2) absorbents. A new absorbent, Amsorb (Armstrong Medical Ltd., Coleraine, Northern Ireland), does not employ these strong bases. This study compared the scavenging efficacy and compound A production of two commercially available absorbents (soda lime ...

متن کامل

Using amsorb to detect dehydration of CO2 absorbents containing strong base.

BACKGROUND Because Amsorb changes color when it dries, the authors investigated whether Amsorb combined with different strong base-containing carbon dioxide absorbents signals dehydration of such absorbents. METHODS Five different carbon dioxide absorbents (1,330 g) each topped with 70 g of Amsorb were dried in an anesthesia machine (Modulus CD, Datex-Ohmeda, Madison, WI) with oxygen (Amsorb ...

متن کامل

Novel radiator for carbon dioxide absorbents in low-flow anesthesia.

During long-term low-flow sevoflurane anesthesia, dew formation and the generation of compound A are increased in the anesthesia circuit because of elevated soda lime temperature. The object of this study was to develop a novel radiator for carbon dioxide absorbents used for long durations of low-flow sevoflurane anesthesia. Eleven female swine were divided into two groups comprising a "radiato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 95 3  شماره 

صفحات  -

تاریخ انتشار 2001