Effect of low-intensity pulsed ultrasound stimulation on gap healing in a rabbit osteotomy model evaluated by micro computed to
ثبت نشده
چکیده
computed tomography-based 3-dimensional cross-sectional moment and cross-sectional moment of inertia Tobita, K; +Ohnishi, I; Matsumoto, T; Ohashi, S; Bessho, M; Kaneko M; Matsuyama, J; Nakamura, K + Department of Orthopaedic Surgery, Faculty of Medicine, University of Tokyo, Tokyo, Japan [email protected] INTRODUCTION Low-intensity pulsed ultrasound stimulation (LIPUS) reportedly enhances restoration of strength at fracture healing sites according to previous experimental studies [1]. However, evaluation of strength by mechanical testing is limited to only one direction, with either bending or torsion. Quantitative micro computed tomography (μCT) is able to acquire 3-dimensional (3D) histomorphometric data and density distributions of hard tissues, from which strength-related parameters can be calculated to allow strength analysis of the tissue. Strength-related parameters such as cross-sectional moment (CSM) and cross-sectional moment of inertia (CSMI) have been used to evaluate strength of the fracture healing site and reportedly correlate well with measured strength from mechanical testing [2]. However, previous studies have performed 2-dimensional (2D) analyses, and 3D evaluations have not been described. The purpose of this study was thus to investigate the effects of LIPUS on osteotomy healing using conducting 3D analyses of strength-related parameters of CSM and CSMI derived from μCT of the osteotomy gap. MATERIALS AND METHODS Surgical Procedures and LIPUS Treatment A total of 42 skeletally mature between 21 and 23-week-old male Japanese white rabbits (Kitayama Labes, Nagano, Japan), weighing 3.44.0 kg, were used for this study. Under general anesthesia, four transfixation pins (diameter, 2 mm; length, 50 mm) were inserted at the metaphyseal regions of the tibia in the frontal plane using a custommade surgical pin driver. Transverse osteotomy was performed using a T-saw (blade thickness, 0.36 mm) with continuous irrigation with saline solution across the mid-shaft of the tibia at 12 mm distal to the tibiofibular junction. The osteotomy with a 2-mm gap was immobilized with four pins fixed to an external fixator with double side bars. The LIPUS system (model SAFHS2000J, Teijin Pharma, Tokyo, Japan), which transmits 200-μsec burst of 1-MHz sine waves repeated at 1kHz with an average intensity of 30mW/cm, was used. After postoperative day 3, LIPUS was continued under general anesthesia for both the treatment group (n=7/group/time point) and the control group (n=7/group/time point). The transducer was placed onto the anterior surface of the operated leg with ultrasound coupling gel, for 20 min, six times/week, for 4, 6, or 8 weeks. The control group also received a sham inactive transducer under exactly the same condition as the LIPUS group. μCT Analysis All animals were euthanized and the entire tibia was removed. The harvested tibia was scanned by μCT system (Scan X mate-E090, Comscantecno, Kanagawa, Japan). The scan was performed along the long axis of the diaphysis, with a voltage of 60 kVp and a current of 80 mA. Scan range covered 5 mm proximal and 5 mm distal to the center of the gap, with a resolution of 28.57 m voxel size. The region of interest (ROI) was set at the callus healing area (Fig. 1) defined by the gap filled with callus in 2D CT and extended 0.5 mm proximally and distally to the center of the osteotomy gap with a total of 36 CT axial scans. 3D reconstruction of mineralized tissue was performed using a TRI-BONE system (Ratoc System Engineering, Tokyo, Japan). A threshold for newly formed mineralized callus was set as 200 mg/cm. Morphometric parameters used for evaluation were mineralized callus volume (BV, cm3) and mineralized callus contents (BMC, mg) calculated from the contoured ROI in 3D images, and volumetric bone mineral density of mineralized tissue comprising the callus (mBMD, mBMD = BMC/BV, mgHA/cm3). Center of gravity for the ROI was calculated automatically. The Z (polar) axis was defined to coincide with the long axis of the tibia. The Y axis was defined as parallel to the transfixation pins, which were also parallel to the posterior surface of the tibia (mediolateral (ML) direction). The X axis was defined as perpendicular to the YZ plane, and was directed anteroposterior (AP) on the tibia (Fig. 2). Three-dimensional CSM and CSMI An optional line (I) can be drawn in this XYZ coordinate. The angle of the Z axis (θ) was measured, and also the degree of angle of the X axis (φ) was measured (Fig. 3). The 3D CSM [I (φ, θ)] around this line was calculated as shown. 3D CSM was calculated using the following equation: I (φ, θ) = ∫ r2dV (mm), where r is the distance of a voxel to the center of gravity (mm) and dV (BV/voxel) is the area of a voxel (mm). The axial CSM was defined as CSMx: I (0, 90), CSMy: I (90, 90), whereas the polar CSM was also defined as CSMp: I (any, 0). We evaluated these three parameters as bone strength indices. 3D CSMI weighted by density distribution was calculated using the following equation: I’ (φ, θ) = ∫ r2dm = ∫ ρr2dV (mgmm2), where r is the distance of a voxel to the center of gravity, dm is the measured mineral content of a voxel in callus (BMC/voxel), ρ is the measured volumetric callus mineral density (mBMD), and dV (BV/voxel) is the area of a voxel (mm). CSMI x: I’ (0, 90), CSMI y: I’ (90, 90), and CSMI p: I’ (any, 0) were calculated. These three parameters were evaluated as bone strength indices. Statistical Analysis The μCT evaluations were analyzed using a one-way ANOVA test. Data were all presented in mean and standard deviation (SD). Statistically significant difference was set at p<0.05.
منابع مشابه
Effect of low-intensity pulsed ultrasound stimulation on callus remodelling in a gap-healing model: evaluation by bone morphometry using three-dimensional quantitative micro-CT.
We evaluated the effect of low-intensity pulsed ultrasound stimulation (LIPUS) on the remodelling of callus in a rabbit gap-healing model by bone morphometric analyses using three-dimensional quantitative micro-CT. A tibial osteotomy with a 2 mm gap was immobilised by rigid external fixation and LIPUS was applied using active translucent devices. A control group had sham inactive transducers ap...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملTHE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR
We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...
متن کاملEffects of Low-Intensity Pulsed Ultrasound on New Trabecular Bone during Bone–Tendon Junction Healing in a Rabbit Model: A Synchrotron Radiation Micro-CT Study
This study was designed to evaluate the effects of low-intensity pulsed ultrasound on bone regeneration during the bone-tendon junction healing process and to explore the application of synchrotron radiation micro computed tomography in three dimensional visualization of the bone-tendon junction to evaluate the microarchitecture of new trabecular bone. Twenty four mature New Zealand rabbits und...
متن کاملEffect of a static magnetic field on bone healing in the dog: radiographic and histopathological studies
Although the promotional effects on bone healing of pulsed electromagnetic fields (PEMF) have beenwell demonstrated, the effects of static magnetic fields (SMF) remained unclear. In this study, effects of acustom-made magnetic wrap on radiographic and histopathological aspects of bone healing using a canineunstable osteotomy gap model were investigated. After an osteotomy of the midshaft radius...
متن کاملبررسی اثر امواج اولتراسوند منقطع با فرکانس پایین بر تشکیل کال استخوانی تیبیا در خرگوش( ارزیابی رادیولوژیک و بیومکانیک)
Background and Objective: Application of low intensity ultrasound has been used for treatment of many diseases in medicine and has suggested for accelerating wound healing process, modifying scar tissue and relief of pain. The aim of this study was radiological and biomechanical evaluation of low-intensity pulsed ultrasound on callus formation of tibia in rabbit. Materials and Methods: In this...
متن کامل