Objective analysis of contact lens fit.

نویسندگان

  • Lurdes Belda-Salmerón
  • Tom Drew
  • Lee Hall
  • James Stuart Wolffsohn
چکیده

PURPOSE To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. METHODS Thirty-five subjects (aged 22.0±3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. RESULTS The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p<0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p>0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128 mm versus ±0.168 mm, p=0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371±0.381 mm) with good inter- and intrasession repeatability (p>0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269±0.179 mm versus 0.352±0.355 mm; p=0.035), but had better repeatability (±0.124 mm versus ±0.314 mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562±0.259 mm) than measured objectively (0.708±0.374 mm, p<0.001), had poorer repeatability (±0.132 mm versus ±0.089 mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p<0.001). CONCLUSIONS The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Consensus on recording of gas permeable contact lens fit.

PURPOSE To develop a new schematic scheme for efficiently recording the key parameters of gas permeable contact lens (GP) fits based on current consensus. METHODS Over 100 established GP fitters and educators met to discuss the parameters proposed in educational material for evaluating GP fit and concluded on the key parameters that should be recorded. The accuracy and variability of evaluati...

متن کامل

The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability.

PURPOSE To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. METHODS Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectivel...

متن کامل

The Mechanics of a Hydrogel Contact Lens on the Human Eye with a Lubricating Tear Layer

The mechanics governing the fit of a soft contact lens on the eye are examined through the development of a finite element analysis model. A linearly elastic lens is placed on a rigid eye with a lubricating viscoelastic tear layer. The mechanics of fit are described in terms of the pressure distribution through the tear layer, the contact pressure at the lens/tear interface, the tear film thick...

متن کامل

How to prevent and treat anysometropic-amblyopic child by contact lenses.

Anisometropy as a first step on a way forward future amblyopic child, can be prevent and treat if this condition is recognased on time. Second step is wisdom, right contact lens fit on bothes eyes. As follow, some ortoptic-pleoptic procedures depending on (objective, subjective squinting angle, state of fusion, visus on bothes eyes and separatly each eay and condition of nervus opticus (VEP), n...

متن کامل

Continuing education CET

● Tear film assessment should be undertaken with minimal invasion of the structure – non-invasive techniques should be used whenever possible ● Assessment must be made both prior to and during contact lens wear. Tear film quality should be assessed both with the lens in situ and without the lens ● Use of the Tearscope in clinical practice allows a more detailed examination of the tears to be un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact lens & anterior eye : the journal of the British Contact Lens Association

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2015