Porcine-specific hemoglobin saturation measurements.

نویسندگان

  • Richard Serianni
  • Jed Barash
  • Timothy Bentley
  • Pushpa Sharma
  • John L Fontana
  • Darin Via
  • Jochen Duhm
  • Rolf Bunger
  • Paul D Mongan
چکیده

The determination of O(2) consumption by using arteriovenous O(2) content differences is dependent on accurate oxyhemoglobin saturation measurements. Because swine are a common experimental species, we describe the validation of CO-oximeter for porcine-specific oxyhemoglobin saturation. After developing a nonlinear mathematical model of the porcine oxyhemoglobin saturation curve, we made 366 porcine oxyhemoglobin saturation determinations with a calibrated blood-gas analyzer and a porcine-specific CO-oximeter. There was a high degree of correlation with minimal variability (r(2) = 0.99, SE of the estimate = 5.2%) between the mathematical model and the porcine-specific CO-oximeter measurements. Bland-Altman comparison showed that the CO-oximeter measurements were biased slightly lower (-0.4 vol%), and the limits of agreement (+/-2 SD) were 0.7 and -1.5 vol%. This is in contrast to a 10-20 vol% error if human-specific methods were used. The results show excellent agreement between the nonlinear model and CO-oximeter for porcine-specific oxyhemoglobin saturation measurements. In contrast, comparison of the porcine-specific oxyhemoglobin saturations with saturations obtained by using human methods highlights the necessity of species-specific measurement methodology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopy.

We present near-infrared spectroscopy measurement of absolute cerebral hemoglobin concentration and saturation in a large sample of 36 healthy elderly (mean age, 85 ± 6 years) and 19 young adults (mean age, 28 ± 4 years). Non-invasive measurements were obtained on the forehead using a commercially available multi-distance frequency-domain system and analyzed using a diffusion theory model for a...

متن کامل

A novel hemoglobin, Bonn, causes falsely decreased oxygen saturation measurements in pulse oximetry.

BACKGROUND A 4-year-old boy and his father exhibited low oxygen saturation measured transcutaneously by pulse oximetry, a finding that could not be confirmed by arterial blood gas analysis. Both patients exhibited slight hemolysis in their blood, and the boy had a microcytic anemia. There was no evidence of hypoxemia or methemoglobinemia. Despite the normal results from the arterial blood gas a...

متن کامل

Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation.

Near-infrared spectroscopy (NIRS) is a noninvasive optical technique to monitor cerebral oxygen saturation at the bedside. Despite its applicability, NIRS has had limited clinical use because of concerns about accuracy, noted by intersubject variability in slope and intercept of the line between NIRS- and weighted-average arterial-cerebrovenous saturation (SMO2). This study evaluated transcrani...

متن کامل

Rapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths

We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations whi...

متن کامل

Determination of deoxyhemoglobin S polymer in sickle erythrocytes upon deoxygenation.

We have used 13C/1H magnetic double-resonance spectroscopy to measure the amount of sickle hemoglobin polymer within sickle erythrocytes as a function of oxygen saturation. We previously showed that the methods of cross-polarization and scalar decoupling could be used to measure accurately the polymer fraction in deoxygenated sickle hemoglobin solutions [Noguchi, C.T., Torchia, D.A. & Schechter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 94 2  شماره 

صفحات  -

تاریخ انتشار 2003