Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
نویسندگان
چکیده
A system for measuring the stump-socket interface pressure was designed and built using a strain gauged type load cell. The system was utilized to study the pressure distribution in the quadrilateral and ischial containment type sockets. Two volunteer trans-femoral amputees fitted with both types of socket participated in the experiments. Pressures were measured while the subjects were standing and during walking. The maximum pressure recorded for standing was 34 kPa and for walking 95 kPa. Comparison made between the two sockets indicated that higher pressures were recorded at the proximal brim of the quadrilateral socket whereas the ischial containment socket produces a more evenly distributed pressure profile. The pressure distribution on the medial and lateral walls of both types of socket were similar but in the anterior and posterior walls, significant differences were noted. The results obtained from this study were compared with those found in published literature and the biomechanics of the two types of socket is discussed.
منابع مشابه
Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the ...
متن کاملEngineering a trans-tibial prosthetic socket for the lower limb amputee.
INTRODUCTION This review addresses the different prosthetic socket designs for trans-tibial amputees, the biomechanics behind the designs and the current state of the field. Of particular focus is the classic patella-tendon bearing (PTB) socket and the more recent sockets manufactured using pressure casting techniques and the theory, biomechanics and clinical implications of the two designs. Me...
متن کاملThe Capability of Fiber Bragg Grating Sensors to Measure Amputees' Trans-Tibial Stump/Socket Interface Pressures
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The s...
متن کاملChanges in interface pressure and stump shape over time: preliminary results from a trans-tibial amputee subject.
Interface stresses and stump shape were measured during sessions over a two-month interval on a trans-tibial amputee subject. Results from thirteen transducer sites monitored during four sessions showed greater interface pressure changes over time at anterior sites than at lateral or posterior locations. There was a trend of decreased pressure with stump swelling and increased pressure for stum...
متن کاملDevelopment of an Air Pneumatic Suspension System for Transtibial Prostheses
The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 211 2 شماره
صفحات -
تاریخ انتشار 1997