Single-Site Robotic Cholecystectomy

نویسندگان

  • Subhashini Ayloo
  • Nabajit Choudhury
چکیده

BACKGROUND Laparoscopic single-incision surgery is fraught with significant technical drawbacks but has witnessed increased growth mainly for its presumed aesthetic advantages. Recently, a single-site robotic platform has been introduced to alleviate some of the technical challenges with laparoscopic single-site surgery, although literature on this topic is scant. The aim of this study is to analyze the experience of a single surgeon with single-site robotic cholecystectomies since the U.S. Food and Drug Administration gave its approval in December 2011, and to evaluate the robotic platform's safety and short-term surgical outcomes. METHODS From February 1st 2012 to February 28th 2013, patients who underwent single-site cholecystectomy at an academic institution in the United States were retrospectively reviewed from a prospectively maintained database. The following variables were analyzed: age, sex, body mass index, previous surgeries, total operative time, port insertion time, docking time, console time, estimated blood loss, closure time, conversion to open or multiport approach, postoperative outcomes for wound infection, bile leak, biliary ductal injury, right hepatic artery injury, reoperations, readmission, and mortality. Indication for cholecystectomy was symptomatic gallbladder disease. No exclusion criteria were used and no cost analysis was performed. RESULTS During the study period, 31 patients were enrolled. The mean patient age, body mass index, weight, and operative time was 33.6 years, 32.2 kg/m2, 86.3 kg, and 81.4 minutes, respectively. There were no conversions to the open or traditional multiport approach, and no major complications of biliary ductal or hepatic artery injury, bile leak, reoperations, or mortality occurred. There was 1 case of superficial wound infection. CONCLUSIONS Single-site robotic cholecystectomy is feasible and safe and requires a minimal learning curve to transition from traditional multiport to single-port robotic cholecystectomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-port robotic cholecystectomy: results from a first human use clinical study of the new da Vinci single-site surgical platform.

OBJECTIVES To report our results from a first human use clinical study with the da Vinci Surgical single-site instrumentation in patients with gallbladder disease and to perform a retrospective comparison with traditional multiport laparoscopic cholecystectomy. DESIGN Ten patients underwent robotic single-port cholecystectomy performed with the da Vinci Si robot and novel da Vinci single-site...

متن کامل

Single-Site Robotic Cholecystectomy

This study aims to introduce an alternative technique for effective single-site robotic cholecystectomy (SSRC) using a reverse port. Proper exposure of Calot’s triangle is critical for safe laparoscopic cholecystectomy. Current robotic surgical systems are useful for singlesite cholecystectomy. However, in exposing Calot’s triangle, the gallbladder is usually retracted in a medial and upward di...

متن کامل

Single-Site Robotic Cholecystectomy at an Inner-City Academic Center

INTRODUCTION We investigate the safety and efficacy of single-site robotic cholecystectomy compared to laparoscopic cholecystectomy at an inner-city academic medical center. MATERIALS AND METHODS Retrospective analysis comparing single-site robotic to laparoscopic cholecystectomies from August 1, 2013, to January 31, 2015, was conducted. Age, gender, race, body mass index (BMI), total operati...

متن کامل

The First Experiences of Robotic Single-Site Cholecystectomy in Asia: A Potential Way to Expand Minimally-Invasive Single-Site Surgery?

PURPOSE Herein, we firstly present the robotic single-site cholecystectomy (RSSC) as performed in Asia and evaluate whether it could overcome the limitations of conventional laparoscopic single-site cholecystectomy. MATERIALS AND METHODS From October 2013 to November 2013, RSSC for benign gallbladder (GB) disease was firstly performed consecutively in five patients. We evaluated these early e...

متن کامل

Single-port robotic cholecystectomy. Initial and pioneer experience in Brazil

The technique of a single-port laparoscopy was developed over the last years as an attempt to lower surgical aggression and improve the aesthetic results of the minimally invasive surgery. A new robotic platform used with the da Vinci® Robotic System Single-Site System® (Intuitive Surgical, Sunnyvale, California, United States) was recently launched on the global market and is still not documen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2014