A Balloon Tipped Catheter for Obtaining His Bundle Electrograms Without

نویسنده

  • RICHARD H. HELFANT
چکیده

A technique for recording His bundle activity in man without fluoroscopic guidance is described. Balloon tipped triOr tetrapolar catheters were designed with pacing electrodes located at the catheter tip, and two fine sensing electrodes 4 and 5 cm behind it. The catheter tip was preformed into a "J" curve. Following percutaneous transfemoral insertion, the catheter is floated to the right ventricle under electrocardiographic control. This tip configuration and the transfemoral route of insertioni typically directs the catheter into an inverted "J" position with its tip in or near the right ventricular apex. Subsequent catheter withdrawal carries the sensing electrodes through the superior portion of the tricuspid valve and permits recording from the His bundle. With this technique His bundle recordings were possible in 23 of 24 patients. Re-advancement into the right ventricular apex permits stable temporary pacing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A balloon tipped catheter for obtaining his bundle electrograms without fluoroscopy.

A technique for recording His bundle activity in man without fluoroscopic guidance is described. Balloon tipped triOr tetrapolar catheters were designed with pacing electrodes located at the catheter tip, and two fine sensing electrodes 4 and 5 cm behind it. The catheter tip was preformed into a "J" curve. Following percutaneous transfemoral insertion, the catheter is floated to the right ventr...

متن کامل

The effect of electrode configuration on the unipolar His-bundle electrogram.

Although "unipolar electrograms" recorded from the His-bundle position have been used to help position catheters for His-bundle ablation, the techniques used to record such electrograms have not been standardized. The effects of five anode locations (right chest wall, anterior chest wall, left chest wall, posterior chest wall, and inferior vena cava) on unipolar atrial, His bundle and ventricul...

متن کامل

Catheter-induced intra-Hisian and intrafascicular block during recording of His bundle electrograms.

or even complete A-V block. Two cases are reported in which catheter-induced transient high grade Mobitz II A-V block, acute reversible prolongation of infranodal conduction time with probable intra-Hisian conduction delay, and persistent (6 hours duration) complete A-V block occurred in patients with left bundle branch block. The observations made indicate that A-V conduction times and the app...

متن کامل

Conduction intervals and conduction velocity in the human cardiac conduction system. Studies during open-heart surgery.

Specialized fiber electrograms were recorded in 64 patients during open-heart surgery. Intervals were measured from the proximal His bundle, distal His bundle, and right and left bundle branches to the earliest QRS deflection in the limb lead ECG (pH-Q, dH-Q, RB-Q, and LB-Q interval, respectively). There was an increase of pH-Q intervals with increasing age such that at age 3 months the normal ...

متن کامل

Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

BACKGROUND Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005