Are gadolinium-based contrast media really safer than iodinated media for digital subtraction angiography in patients with azotemia?

نویسندگان

  • Ulf Nyman
  • Barbara Elmståhl
  • Peter Leander
  • Mats Nilsson
  • Klaes Golman
  • Torsten Almén
چکیده

Gadolinium chelates, intended as intravenous contrast media for magnetic resonance imaging, have been regarded as nonnephrotoxic and recommended to replace iodinated contrast media in patients with azotemia who are undergoing digital subtraction angiography (DSA). High intraarterial doses (up to 220 mmol of gadodiamide) have been used, with a 40% incidence of nephropathy. The authors discourage the use of gadolinium for DSA for several reasons. (a) There exist no randomized studies comparing the nephrotoxic effects of gadolinium-based and iodinated media at equal-attenuating concentrations and doses. (b) Gadolinium-based media are hypertonic, a pathogenetic factor in contrast medium-induced nephropathy after renal angiography, with an osmolality two to seven times that of plasma. Iodinated media in concentrations that are equally attenuating with gadolinium-based media can be made isotonic. (c) In vitro measurements indicate that 0.5 mol/L gadolinium chelates are equally attenuating with 60-80 mg iodine per milliliter at the commonly used 70-90-kV range used for DSA. Thus, 50 mL of 0.5 mol/L gadolinium chelate ( approximately 0.3 mmol/kg in an 80-kg person) would be equally attenuating with a dose of 3-4 g of iodine in an iodinated medium (eg, 50 mL iohexol at 60-80 mg I/mL or 10-13 mL at 300 mg I/mL). (d) By combining these data on attenuation and results of toxicity studies in mice, the general toxicity of gadolinium chelates may be six to 25 times higher than that of equal-attenuating doses of iodinated media at 70-kV DSA. Thus, the authors believe that at equal-attenuating doses for DSA, modern iodinated contrast media should result in a lower toxic load on the body than with presently available gadolinium chelates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral angiography using gadolinium as an alternative contrast medium in a patient with severe allergy to iodinated contrast medium.

We report cerebral digital subtraction angiography (DSA) using Gadolinium in a patient allergic to iodinated contrast media. A 77-year-old woman was admitted to our hospital for surgical resection of a brain tumor. Although a DSA was requested as a preoperative examination, the patient had a history of allergic reaction to non-ionic iodinated contrast medium. Therefore, DSA was performed using ...

متن کامل

Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients.

BACKGROUND To determine whether gadolinium-based contrast media (CM) could be used safely for angiographies in patients with renal dysfunction we investigated renal function after gadobutrol exposure and compared the results with standard iodinated CM (iohexol) in a randomized clinical study. METHODS Twenty-one patients (aged 67+/-11 years, nine female and 12 male) with severely impaired rena...

متن کامل

Regarding "Safety of gadolinium contrast angiography in patients with chronic renal insufficiency".

OBJECTIVE To prevent iodinated contrast medium-induced nephrotoxicity, gadolinium has been used increasingly for magnetic resonance angiography (MRA) or conventional digital subtraction angiography (DSA) to visualize arterial anatomy in patients undergoing vascular surgery who are considered at high risk because of chronic renal insufficiency. We assessed the safety of gadolinium-based contrast...

متن کامل

Vascular Intervention Carbon Dioxide Digital Subtraction Angiography for A Renal Artery Stent Placement 1

MATERIALS AND METHODS: Seventeen hypertensive patients with renal ostial stenosis were evaluated and underwent stent placement with use of CO, digital subtraction angiography (DSA). Besides hypertension, 11 patients had decreased renal function, three had iodinated contrast material allergy, one patient had both, and two had neither. Supplemental iodinated contrast material (25 mL or less) was ...

متن کامل

Lower limb angiography: a prospective study comparing carbon dioxide with iodinated contrast material in 30 patients.

OBJECTIVE We prospectively compared patients' tolerance for and the usefulness of carbon dioxide (CO2) with iodinated contrast material in the study of lower limb arteries in 30 patients. SUBJECTS AND METHODS We systematically performed digital subtraction angiography with electronic injection of CO2 (injection average, 330 ml) and digital subtraction angiography with iodinated contrast mater...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 223 2  شماره 

صفحات  -

تاریخ انتشار 2002