Human Adipocyte Apoptosis Immediately Following High Frequency Focused Field Radio Frequency: Case Study.

نویسندگان

  • David McDaniel
  • Paula Lozanova
چکیده

BACKGROUND A previously published study used a radio frequency (RF) focused field device (Vanquish, BTL Industries Ltd., Framingham, MA) to reduce porcine abdominal fat. The purpose of this case study was to reproduce the veterinary study on human subjects. The primary objective was measurement of apoptotic index before and after treatment with the RF device. As a second outcome demonstrating selective heating and safety, superficial skin temperature and temperature 1 and 2 cm into the subcutaneous tissue were measured. METHODS AND MEASUREMENTS Two healthy female subjects underwent abdominal skin and fat biopsies at baseline and after one treatment with a similar focused field high frequency RF device capable of 200 watts for 45 minutes. Biopsies were performed 1 hour post-treatment and were analyzed using the TUNEL method. Infrared imaging of the skin surface temperature was measured in both subjects. Thermocouple measurements at 1 and 2 cm were performed during the treatment cycle on a single subject. RESULTS Histologic apoptotic index (pre and 1 hour post) showed an average increase of 487% (6.5 to 31.7). Thermal imaging demonstrated an average surface temperature of 31.6C° pre-treatment and 39.2°C post-treatment. The 1 cm depth thermocouple showed an initial temperature of 40C° and reached a maximum of 45°C 15 minutes into the treatment. It remained stable at 45°C for the remaining 30 minutes treatment time. No adverse events were noted. CONCLUSION RF treatment induces an increase in apoptotic index in adipocytes 1 hour post-RF treatment. This is accompanied by a peak temperature of 45°C in the fat layer. Skin surface temperatures remain substantially lower than fat temperatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Design and Implementation of Field Programmable Gate Array Based Baseband Processor for Passive Radio Frequency Identification Tag (TECHNICAL NOTE)

In this paper, an Ultra High Frequency (UHF) base band processor for a passive tag is presented. It proposes a Radio Frequency Identification (RFID) tag digital base band architecture which is compatible with the EPC C C2/ISO18000-6B protocol. Several design approaches such as clock gating technique, clock strobe design and clock management are used. In order to reduce the area Decimal Matrix C...

متن کامل

Magnetoreception in birds: the effect of radio-frequency fields.

The avian magnetic compass, probably based on radical pair processes, works only in a narrow functional window around the local field strength, with cryptochrome 1a as most likely receptor molecule. Radio-frequency fields in the MHz range have been shown to disrupt the birds' orientation, yet the nature of this interference is still unclear. In an immuno-histological study, we tested whether th...

متن کامل

Blood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

متن کامل

A Novel SOI MESFET by Implanted N Layer (INL-SOI) for High Performance Applications

This paper introduces a novel silicon-on-insulator (SOI) metal–semiconductor field-effect transistor (MESFET) with an implanted N layer (INL-SOI MESFET) to improve the DC and radio frequency characteristics. The DC and radio frequency characteristics of the proposed structure are analyzed by the 2-D ATLAS simulator and compared with a conventional SOI MESFET (C-SOI MESFET). The simulated result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of drugs in dermatology : JDD

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2015