Automated on-line separation–preconcentration system for platinum determination by electrothermal atomic absorption spectrometry

نویسندگان

  • C. Bosch Ojeda
  • F. Sánchez
چکیده

A flow injection on-line sorption preconcentration system for the electrothermal atomic absorption spectrometric determination of platinum has been developed. The method employs on-line preconcentration of platinum on a column packed with silica gel functionalised with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide (DPTH-gel) placed in the autosampler arm. The modification of the autosampler in the tubing line and circuit allowed either the flow of the sample through the column or the operation of the autosampler in the normal mode, where microlitres of 2 M HNO3, which acts as the elution agent, pass through the microcolumn eluting Pt(IV), which is directly deposited in the graphite tube as a drop of a precisely defined volume. An enrichment factor of 41.7 and a 3σ detection limit of 0.8 ng ml−1 along with a sampling frequency of 29 h−1 are achieved with 60 s preconcentration time at a sample flow rate of 2.4 ml min−1. The relative standard deviation is 1.6% for 4 ng ml−1 Pt (n = 11). The method has been applied to the determination of platinum in catalyst, vegetation, soil and water samples. © 2003 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy

At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...

متن کامل

Determination of platinum by graphite furnace atomic absorption spectrometry in foods and beverages using an automated on-line separation-preconcentration system

The increasing use of automobile catalysts leads to the emission of the platinum-group elements (PGE), mainly platinum, but also rhodium and palladium into the environment. In environmental samples, the low concentration of platinum together with the high concentration of interfering matrix components often requires a preconcentration/enrichment step combined with a matrix-separation. The metho...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

Automated on-line separation preconcentration system for palladium determination by graphite furnace atomic absorption spectrometry and its application to palladium determination in environmental and food samples.

A flow injection (FI) system was used to develop an efficient on-line sorbent extraction preconcentration system for palladium by graphite furnace atomic absorption spectrometry (GFAAS). The investigated metal was preconcentrated on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The palladium is eluted with 40mul of HCl 4M and d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003