One-hour serum xylose as an absorption test in the tropics.

نویسندگان

  • P G Hill
  • I N Ross
  • R Jacob
  • S Jyotheeswaran
  • V I Mathan
چکیده

The 1-hour serum xylose (surface area corrected) as an indication of xylose absorption after 5 g oral D-xylose has been compared with the 5-hour urine excretion test in a tropical population. The study confirmed that the peak serum xylose concentration occurs at 1 hour and that correction to a constant body surface are improves the discrimination between subjects with normal and impaired xylose absorption. The significantly lower reference range for the 1-hour surface area corrected serum xylose (0.55-1.11 mmol/l) compared to the UK figure reflects the reduced absorptive capacity of the jejunum, a result of tropical enteropathy. In view of the difficulties in obtaining accurate urine collections in tropical countries, especially in field studies, it is recommended that the 1-hour serum xylose (surface area corrected) should be adopted as the standard test of xylose absorption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alteration of D-xylose intestinal absorption in broilers with high dietary barley intake

Low nutritive value and suitability of barley as a feedstuff for broilers is mainly due to its non-starch polysaccharides. An experiment was carried out to evaluate if diets high in barley alter the mechanisms responsible for the absorption of nutrients across the intestinal epithelium of broilers, using D-xylose absorption test. Thirty, 14-d old male broiler chicks (Ross 308) with similar body...

متن کامل

Jejunal monosaccharide, water, and electrolyte transport in patients with chronic pancreatitis.

Jejunal perfusion studies were performed to assess water, electrolyte, d-xylose, and d-glucose transport in 16 patients with chronic calcific pancreatitis (eight with and eight without steatorrhoea) and in 10 control subjects. The patients with steatorrhoea demonstrated significantly less xylose, water, and electrolyte absorption than patients without steatorrhoea and control subjects, when an ...

متن کامل

Neonatal gut function, measured by the one hour blood D (+) xylose test: influence of gestational age and size.

D(+) Xylose absorption, assessed by one hour blood xylose levels, has been measured after intraduodenal infusion of the sugar in 35 infants of differing gestational age and size. The test was performed between the 2nd and 6th days of life. Full-term appropriately grown infants had higher blood xylose levels (1.41+/-0.07 mmol/l) at one hour than pre-term appropriately grown infants (1.17+/-0.07 ...

متن کامل

Differences in Intestinal Absorptive Capacity of Chickens for D-Xylose

Background: According to literature, there are differences among different species of animals in respect to absorption of D-xylose. OBJECTIVES: In two experiments, the differences that might exist in absorptive capacity of small intestine for D-xylose, in different types of chicken were tested. METHODS: In experiment one, 2 groups of nine adult layer type males (48 weeks) and females (58 weeks)...

متن کامل

Confirming persistence of gluten intolerance in children diagnosed as having coeliac disease in infancy.

In young infants the clinical and investigative features of coeliac disease (CD) may be mimicked by other conditions such as cow's milk intolerance or secondary disaccharidase deficiency. It is therefore especially important to confirm a diagnosis of CD by later gluten challenge in such infants. Sixteen children in whom the diagnosis of CD had been made before the age of 12 months had an oral g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 1981