Effects of dialyser and dialysate on the acute phase reaction in clinical bicarbonate dialysis.

نویسندگان

  • W E Schouten
  • M P Grooteman
  • A J van Houte
  • M Schoorl
  • J van Limbeek
  • M J Nubé
چکیده

BACKGROUND In chronic haemodialysis (HD), morbidity may result from repetitive induction of the acute phase response, caused by a bioincompatible dialysis membrane and/or contaminated dialysate. In the present study, cytokine release (interleukin-6, IL-6) and subsequent production of acute phase proteins (C-reactive protein, CRP and secretory phospholipase A(2), sPLA(2)) were assessed to investigate whether the HD-induced acute phase reaction depends mainly on the type of membrane or on the sterility of the dialysate. METHODS In 11 patients, IL-6, CRP and sPLA(2) levels were assessed in blood samples drawn before (t(0)), at the end (t(180)) and 24 h after the start of HD (t(1440)). All patients were dialysed on Cuprammonium (CU) and Polysulphon (PS) dialysers and seven patients underwent an additional HD session on CU plus a dialysate filter (CUf). RESULTS IL-6 levels were increased significantly at t(180) compared with t(0) (P<0.02) with both CU and CUf. At t(1440), IL-6 levels had returned to baseline. In contrast, marked fluctuations did not occur during HD with PS. At t(180), IL-6 was significantly greater with CU and CUf devices, than with PS (P<0.02). Following HD with CU and CUf, a significant increase in CRP was observed at t(1440), compared with postdialysis values (P</=0.05). In addition, sPLA(2) values were markedly increased at t(1440), compared with t(180), but only significant in the case of CU (P=0.01). IL-6 levels at t(180) were significantly correlated with CRP (r=0.50, P<0.01) and sPLA(2) (r=0.47, P=0.01) values at t(1440). During HD with PS membranes, neither CRP nor sPLA(2) values were markedly changed. CONCLUSIONS In contrast to PS, both CU and CUf resulted in elevated IL-6 plasma levels at the end of HD, compared with t(0), which correlated with increased CRP and sPLA(2) values 24 h later. Therefore, the type of membrane, rather than the bacterial quality of the dialysate, seems to be responsible for the induction of the acute phase response during clinical bicarbonate HD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparision between effects of bicarbonate and acetate dialysates on spirometry parameters in patients with chronic renal failure undergoing hemodialysis

Introduction: Chronic renal failure causes impairment of all body organs including heart and lungs. Main problem in these patients are pulmonary edema due to increased permeability of capillaries, intravascular and interstitial volume overload, hypertension and heart failure. These changes cause altered physiologic and mechanical function of lungs. The objective of this study is evaluating the ...

متن کامل

اثر نوع محلول بافر همودیالیز در کنترل فشارخون و کفایت دیالیز بیماران همودیالیزی مزمن

Background: The effect of kind of dialysis solution on the control of blood pressure and adequacy and efficacy of hemodialysis is a most debated and controversial issue. Methods: Twenty six chronic hemodialized patients in Ghaem hemodialysis center, Mashhad, Iran, in winter of the year 2004, enrolled this study for one month. The patients were dialyzed with bicarbonate buffer and were dialy...

متن کامل

Automated peritoneal dialysis with 'on-line'-prepared bicarbonate-buffered dialysate: technique and first clinical experiences.

BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based...

متن کامل

Post-Dilution on Line Haemodiafiltration with Citrate Dialysate: First Clinical Experience in Chronic Dialysis Patients

BACKGROUND Citrate has anticoagulative properties and favorable effects on inflammation, but it has the potential hazards of inducing hypocalcemia. Bicarbonate dialysate (BHD) replacing citrate for acetate is now used in chronic haemodialysis but has never been tested in postdilution online haemodiafiltration (OL-HDF). METHODS Thirteen chronic stable dialysis patients were enrolled in a pilot...

متن کامل

Anticoagulation during haemodialysis using a citrate-enriched dialysate: a feasibility study.

BACKGROUND The feasibility of anticoagulating the extracorporeal circuit during haemodialysis using a simple citrate-enriched dialysate was evaluated in a prospective, randomised, cross-over study of 24 patients who were at high risk for bleeding. METHODS A dialysate, with a citrate level of 3 mEq/L (1 mmol/L), was generated by adding citrate to the conventional liquid 'bicarbonate concentrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2000