Toxicological screening of drugs by microbore high-performance liquid chromatography with photodiode-array detection and ultraviolet spectral library searches.

نویسندگان

  • A Turcant
  • A Premel-Cabic
  • A Cailleux
  • P Allain
چکیده

We use ultraviolet data, acquired with a photodiode-array detector coupled to a reversed-phase liquid-chromatographic system, to identify unknown drugs in plasma samples of acutely poisoned patients. Both retention time and spectra of the peaks obtained with a microbore Hypersil ODS column under gradient elution are compared with a library of approximately 350 compounds. We present our three-year experience with this system, which identifies drugs in less than 1 h, with a high degree of confidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential of high-performance liquid chromatography with photodiode array detection in forensic toxicology.

The potentials and limitations of high-performance liquid chromatography-photodiode array detection are highlighted in respect to its use in the analysis of different biological matrices followed by the identification of unknowns. The logical analytical approach used in clinical and forensic toxicology, vital for the identification of one or more toxic substances as a cause of intoxication, is ...

متن کامل

Uniform solid-phase extraction procedure for toxicological drug screening in serum and urine by HPLC with photodiode-array detection.

In this HPLC-diode-array detection method for toxicological drug screening, a mixed-mode solid-phase extraction procedure is optimized for isolation of a broad range of drugs from serum and urine. Basic, neutral, and weakly acidic drugs are uniformly recovered. The extract from the solid-phase cartridge is readily injected to a reversed-phase HPLC column for separation by gradient elution. Unkn...

متن کامل

Emergency toxicology testing (detection, confirmation, and quantification) of basic drugs in serum by liquid chromatography with photodiode array detection.

We investigated the applicability of liquid chromatography with photodiode array detection as a serum drug screening technique in an emergency toxicology setting. Basic compounds are extracted from alkalinized serum with hexane and chromatographed on a cyanopropyl reversed-phase column. The photodiode array detector records the ultraviolet spectrum of each eluting peak for identification and qu...

متن کامل

TOXINS: CHROMATOGRAPHY See III /MARINE TOXINS: CHROMATOGRAPHY; NEUROTOXINS: CHROMATOGRAPHY TRACE ELEMENTS BY COPRECIPITATION: EXTRACTION

substances and its interlaboratory use. Journal of Chromatography A 674: 97}126. Clauwaert KM, Van Bocxlaer JF, Lambert WE and De Leenheer AP (1997) Liquid chromatographic determination of cocaine, benzoylecgonine, and cocaethylene in whole blood and serum samples with diode-array detection. Journal of Chromatographic Science 35: 321}328. Gaillard Y and PeH pin G (1997) Use of high-performance ...

متن کامل

Determination of psychotropic phenylalkylamine derivatives in biological matrices by high-performance liquid chromatography with photodiode-array detection.

Several procedures using high-performance liquid chromatography with photodiode-array detection have been developed to create phytochemical and toxicological profiles of phenylalkylamine derivatives in biological samples (e.g. plant materials and urine). Mescaline-containing cactus samples were extracted with basic methanol, using methoxamine as internal standard; the extraction and clean-up of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 1991