Mathematical Calibration of a Whole-Body Counter

نویسنده

  • Martin Schläger
چکیده

This paper describes the mathematical efficiency calibration of the whole-body counter at Forschungszentrum Jülich using Monte Carlo codes and mathematical anthropomorphic phantoms. As a prerequisite for the Monte Carlo simulations a precise model of the 4 high-purity germanium (HPGe) detectors had to be developed. Because the technical data provided by the manufacturer were not sufficient for this purpose, more reliable information about the constructional features was obtained by scanning measurements with collimated radiation at the front window and the sides of each detector. Efficiency calibrations were performed for many different combinations of body height, weight and photon energy. The required efficiency values for the whole energy range of interest (50 keV − 2 MeV) were simulated with the Monte Carlo codes MCNP 4C2 and MCNP 5 using a detailed geometrical model of the detectors and various Medical Internal Radiation Dose (MIRD) phantoms representing adults and children. The dependence of the efficiency on height and weight of the measured person is discussed. The calculated efficiency curves based on mathematical MIRD phantoms were compared with conventional calibration results from measurements of bottle phantoms and brick phantoms. Generally, good agreement was found between the simulated and experimental results. In a sensitivity analysis simulations with MIRD phantoms were used to analyse the influence of possible sources of error (such as an incorrect position of the measured person or the detectors) on the accuracy of whole-body counting results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Mathematical Phantom to Precise Calibration for Whole-body Counting

INTRODUCTION The calibration of whole-body counter (WBC), that means the determination of the body burden of radionuclides, is generally carried out by comparing the measurements between the human body and the standard calibration phantom. The measured counting efficiency is affected by the deference of size, shape and distribution of radioactivity between them. Therefore, if the standard phant...

متن کامل

In-Vivo Calibration of a LE Ge detection system for the assessment of Americium in bone, in the Whole Body Counter of CIEMAT

The calibration of a LE Ge detector system has been performed at CIEMAT Whole Body Counter for the assessment of Am in skull and knee. The facility counts with a Cohen phantom simulating a human head with 1000 Bq of Americium homogeneously distributed in the bone equivalent material. Measurements of the LE Ge system with the skull phantom were carried out in an optimisation study of counting ef...

متن کامل

Evaluation of Counting Efficiency of Whole–body Counter using Voxel Phantoms

The calibration methods for in vivo measurement systems using Monte Carlo simulations and voxel phantoms have been demonstrated. The calibration data, such as counting efficiency or response function, calculated by the UCWBC code that was developed in the Japan Atomic Energy Research Institute were compared with those measured with an in vivo measurement system. It was found that the calibratio...

متن کامل

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration

INTRODUCTION: In Vivo measurements use radiation detectors, such as NaI, that require calibration using a source that is both geometrically and materially similar to the actual sample to be measured. In the case of whole body counting, the sample being measured is a person. Traditionally, BOttle Mannikin ABsorber (BOMAB) phantoms have been used for this purpose. A BOMAB phantom usually consists...

متن کامل

Whole body phantoms for the determination of dosimetry parameters needs for patients in nuclear medicine [Persian]

This study aims to give data concrning phantom material made in Iran i'rom a natural rubber which is used for obtaining calibration data for patient dose measurements in nuclear medicine applications of radionuclides for therapy and diagnosis. Is showed to be a tissue equivalent material cheap (25000 Rials the material itself and 35000 Rials the process of casting and moulding etc.), easi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008