Single-feed quadrature coils as transceiver array elements for improved SNR and transmit efficiency
نویسندگان
چکیده
INTRODUCTION: Quadrature or circularly polarized (CP) coils are desired in MR experiments due to their improved MR sensitivity (by 40%) and reduced excitation power (by half) compared with linear coils. This is particularly true in parallel imaging and parallel excitation where the reception/excitation acceleration demands highly efficient receive and transmit. Conventionally quadrature coils are driven from two feeding ports. In surface coils, which usually serve as resonant elements in parallel imaging coil arrays, the quadrature mode is usually formed by using two loops orthogonal to each other. Their bulky structure limits their application to designing parallel imaging arrays. Soutome and co-worker proposed a method for single-feed birdcage coil and demonstrated its feasibility at 1.5T (1). In this work, we propose a method to generating quadrature modes by single-feed surface coil for high field MR applications. This method is based on the single-feed CP microstrip patch resonator technology. To demonstrate the concept, a single-feed quadrature coil array with two elements was designed and evaluated by using FDTD simulation and bench test.
منابع مشابه
Double Tuned 31P/1H Elliptical Transceiver Phased Array for the Human Brain Studies at 7 T
Introduction: The improved SNR at 7T provides significant advantages for both H and lower gyromagnetic nuclei such as P, Na and C (X nuclei). Double resonant volume head coils, based on both birdcage (1-3) and TEM (4) designs have been previously used at lower magnetic fields. However at 7T, transceiver phased arrays provide significant advantages for both B1 homogeneity and transmit efficiency...
متن کاملFour Channel Transceiver Array for Functional Magnetic Resonance Spectroscopy in the Human Visual Cortex at 9.4 T
Introduction: Functional magnetic resonance spectroscopy (fMRS) at ultra-high field (UHF) strength (≥7T) is a method to investigate the metabolism of the human brain during task induced stimulation [1] or pharmalogical challenge [2]. A region of special interest is the visual cortex which undergoes metabolic changes during visual stimulation [1]. The UHF thereby allows for increased spectral an...
متن کاملA 16-channel Arterial Spin Labeling - Head Transceiver Array Combination for 7 Tesla
Target Audience: RF Engineers, UHF Labs, Researchers interested in pTX, TOF and ASL Purpose The aim of this work was to develop a 7 Tesla Arterial Spin Labeling (ASL) [1,2] transceiver coil array capable of being used as a stand-alone array [3,4] or in combination with an additional transceiver head array [5]. The transceiver design is potentially beneficial at 7T since it allows for Radio Freq...
متن کاملThree Dimensional Spectroscopic Imaging in the Prostate with a Surface Combined Endorectal Coil at 7 Tesla
INTRODUCTION: The benefits of performing prostate spectroscopy at 7T include increased spectral and spatial resolution. The potential exists to be able to better quantify individual metabolites, localize smaller volumes of disease and better monitor disease progression or treatment response. However, spectroscopy in the body at 7T faces many challenges including the well described destructive i...
متن کاملActively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems
Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...
متن کامل