Patient Perceptions and Preferences for a Mealtime Insulin Delivery Patch

نویسندگان

  • Mark Peyrot
  • Darlene Dreon
  • Vivien Zraick
  • Brett Cross
  • Meng H. Tan
چکیده

INTRODUCTION A basal-bolus insulin regimen is needed to achieve glycated hemoglobin A1c (HbA1c) below 7.0% in people with type 1 (T1D) or type 2 (T2D) diabetes who have significant loss of beta-cell function. Nonadherence to therapy is common and negatively affects the ability to reach treatment goals. We examined patient assessment of a new, wearable mealtime insulin-delivery system (patch) relative to their current mealtime insulin-delivery system (syringe, pen, or pump). The patch is designed to deliver only boluses of fast-acting insulin (no basal insulin), mechanically controlled by the patient. METHODS Adults (n = 101) with T1D or T2D assessed their current mealtime insulin-delivery system and then assessed simulated (no active medication) patch use over a 3-day period. Participants evaluated mealtime insulin-delivery systems using eight measures from five domains (convenience, interference with daily activities, diabetes-related worry, psychological well-being, and overall satisfaction/preference) on the self-administered Insulin Delivery System Rating Questionnaire. User ratings of their current insulin-delivery systems (syringe, pen, pump) were compared with those for the patch by repeated measure analysis of variance and one-sample t tests. RESULTS Participants had significant (p < 0.05) preference for patch over syringe in all eight comparisons, and over pen in five out of eight comparisons, with no significant preference for pen. Although there was a preference for patch over pump in six out of eight comparisons, only one showed a significant preference for patch, and one for pump. Significantly more participants reported that they would like to switch to the patch than continue using a syringe (78% vs 22%) or pen (76% vs 24%) but this difference was not significant for the group using a pump (52% vs 48%). CONCLUSIONS Participants preferred using the patch over pens and syringes. Its ease of use and discreet method of insulin delivery may contribute to improved patient adherence to mealtime insulin regimens among people currently using injection devices. FUNDING Calibra Medical.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a novel insulin bolus-patch with pen/syringe injection to deliver mealtime insulin for efficacy, preference, and quality of life in adults with diabetes: a randomized, crossover, multicenter study.

OBJECTIVE This study compared the efficacy, safety, device satisfaction, and quality of life (QOL) in people with diabetes using an insulin bolus-patch versus current devices (pen/syringe) to deliver mealtime insulin. RESEARCH DESIGN AND METHODS Thirty-eight subjects with diabetes (26 with type 1 and 12 with type 2) were randomized to bolus-patch or current injection device (55% pen and 45% s...

متن کامل

A qualitative study of professional caregivers' perceptions of processes contributing to mealtime agitation in persons with dementia in nursing home wards and strategies to attain calmness

AIM Describe professional caregivers' perceptions of factors and processes contributing to mealtime agitation and strategies for attaining and maintaining calm mealtimes. DESIGN Qualitative and descriptive. METHODS A convenience sample of professional caregivers working in two wards for residents with dementia was used. Data were collected during two focus-group interviews and supplemented ...

متن کامل

Transdermal Delivery of Insulin by Biodegradable Chitosan Nanoparticles: Exvivo and In vivo Studies

      Insulin-loaded biodegradable chitosan nanoparticle was prepared by the polyelec-trolyte complex formation method. The prepared nanoparticles were in the size of 110 nm and had high entrapment (91.0%) capacity. The transdermal nanoinsulin was characterized by in vivo hypoglycemic effects. Plasma glucose was decreased to the range of 80.34 to 96.74 mg/dl, and insulin levels were in...

متن کامل

Validity and reliability of an instrument for assessing health-related quality of life and treatment preferences: the Insulin Delivery System Rating Questionnaire.

OBJECTIVE To provide a preliminary assessment of the validity and reliability of a new measure of health-related quality of life (HRQOL) and treatment preference for insulin delivery systems. RESEARCH DESIGN AND METHODS Study participants were 197 adults with type 1 or type 2 diabetes who completed the Insulin Delivery System Rating Questionnaire (IDSRQ), a self-administered questionnaire dev...

متن کامل

The Mealtime Challenge: Nutrition and Glycemic Control in the Hospital

Management of diabetes and hyperglycemia has become an important quality care indicator in the hospital setting. Multiple health care organizations offer guidelines for glycemic control, including recommendations for medical nutrition therapy (MNT) and consistent-carbohydrate meal plans.1–4 Additionally, the appropriate timing of nutrition delivery, point-ofcare (POC) blood glucose monitoring, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2018