A dose-volume intercomparison of volumetric-modulated arc therapy, 3D static conformal, and rotational conformal techniques for portal vein tumor thrombus in hepatocellular carcinoma

نویسندگان

  • Ryo Ogino
  • Masako Hosono
  • Kentaro Ishii
  • Daisaku Tatsumi
  • Shinichi Tsutsumi
  • Yoshitaka Miki
  • Yutaka Masuoka
  • Yasuhiko Shimatani
  • Yukio Miki
چکیده

We created volumetric-modulated arc therapy (VMAT) plans for portal vein tumor thrombus (PVTT) in hepatocellular carcinoma, and compared the results with those from three-dimensional conformal radiotherapy (3D-CRT) and rotational conformal radiotherapy (R-CRT) plans. CT scan data from 10 consecutive patients with PVTT treated with 3D-CRT between January 2008 and January 2010 were utilized in the analysis. We analyzed the dosimetric properties of the plans for the 10 patients using the three different techniques with three different isocenter doses of 50, 56 and 60 Gy in 2-Gy fractions. The D95, Dmean, homogeneity index and conformity index were compared for the planning target volume (PTV). The Dmean, V20 and V30 were also compared for normal livers. The monitor units (MUs) and the treatment time were also evaluated. The normal liver V30 for VMAT was significantly less than that for 3D-CRT for the prescribed doses of 56 and 60 Gy (P < 0.05). It was also found that the normal liver V30 resulting from 3D-CRT was prohibitively increased when the prescribed dose was increased in two steps. For PTV D95, we found no significant differences between the three techniques for the 50- and 56-Gy prescriptions, or between VMAT and the other techniques for the 60-Gy prescription. The differences in the MUs and treatment times were not statistically significant between VMAT and 3D-CRT. We have demonstrated that VMAT may be a more advantageous technique for dose escalation reaching 60 Gy in the treatment of PVTT due to the reduced normal liver V30.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Automatic Segmentation of the Gross Tumor Volume in Prostate Carcinoma Using Fuzzy Clustering in Gallium-68 PSMA PET/CT Scan

Introduction: Modern radiotherapy (RT) techniques allow a highly precise deposition of the radiation dose in tumor. So, high conformal tumor doses can be reached while sparing critical organs at risk. Materials and Methods: This study was conducted in three phases. In the first phase; Fourteen patients with primary or recurrent prostate cancer receive Gallium-...

متن کامل

Treatment planning for the lung cancer

Volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) are commonly used treatment techniques for cancer treatment, and both the VMAT and IMRT techniques use the photon beam (mega-voltage X-rays) to deliver radiation dose to the tumor. The capability of modulating radiation beam has increased the ability of delivering more conformal dose distributions to tumor ...

متن کامل

A dosimetric comparison of three‐dimensional conformal radiotherapy, volumetric‐modulated arc therapy, and dynamic conformal arc therapy in the treatment of non‐small cell lung cancer using stereotactic body radiotherapy

This study evaluates three-dimensional conformal radiotherapy (3D CRT), volumetric-modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning techniques using dosimetric indices from Radiation Therapy Oncology Group (RTOG) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013