Novel methodology to determine the accuracy of the OmniPod insulin pump: a key component of the artificial pancreas system.

نویسندگان

  • Howard Zisser
  • Marc Breton
  • Eyal Dassau
  • Kateryna Markova
  • Wendy Bevier
  • Dale Seborg
  • Boris Kovatchev
چکیده

BACKGROUND This article describes two novel and easy approaches for assessing the accuracy of insulin pumps as implemented within the artificial pancreas system. The approaches are illustrated by data testing the OmniPod Insulin Management System at its lowest delivery volume (0.05 U) and at doses of 0.1, 0.2, 1, and 6U. METHOD In method 1, a pipette, digital microscope, and imaging software were used to measure average bolus delivery on a linear scale for multiple volumes. In method 2, a digital microscope and imaging software were used to measure the volume of a spherical bolus of 0.05 U of insulin. RESULTS Bench testing results using the two novel methods demonstrated that the OmniPod is extremely accurate, with a relative error ranging from -0.90% to +0.96% for all measured doses (0.05, 0.1, 0.2, 1, and 6 U). In method 1, at target bolus dose of 0.05 U, the mean delivered dose (± standard deviation) was 0.0497 ± 0.003 U, 0.099 ± 0.005 U at 0.1 U, 0.2 ± <1e-5 U at 0.2 U, 1.001 ± 0.018 U at 1 U, and 6.03 ± 0.04 U at 6 U. In method 2, at target bolus dose of 0.5 ml, the mean delivered dose for both OmniPods was 0.505 ± 0.014. CONCLUSIONS Both methods confirmed a high degree of accuracy for the OmniPod insulin pump. These techniques can be used to estimate delivery volume in other infusion pumps as well.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of novel methods to determine the accuracy of the OmniPod insulin pump: a key component of the artificial pancreas system.

In this issue of Journal of Diabetes Science and Technology, Zisser and collegues describe two inexpensive methods for accurate measurement of dosage delivered by OmniPod insulin pump. The first method is based on imaging a meniscus movement in a micro-pipette and using simple image analysis; the second relies on using a digital microscope to measure the volume of a dispensed droplet while it i...

متن کامل

The OmniPod Insulin Management System: the latest innovation in insulin pump therapy

This review of insulin pump therapy focuses on the OmniPod® Insulin Management System (Insulet Corp., Bedford, MA, USA). The OmniPod System is the first commercially available "patch pump." It is a fully integrated wearable pump, controlled wirelessly through a handheld device containing a built-in blood glucose meter. This is an evaluation of the OmniPod System, with the aim of providing an ed...

متن کامل

Optimal intelligent control for glucose regulation

This paper introduces a novel control methodology based on fuzzy controller for a glucose-insulin regulatory system of type I diabetes patient. First, in order to incorporate knowledge about patient treatment, a fuzzy logic controller is employed for regulating the gains of the basis Proportional-Integral (PI) as a self-tuning controller. Then, to overcome the key drawback of fuzzy logic contro...

متن کامل

News About the Treatment of Diabetes with Insulin

One of the most important advances in imsulin therapy has been the commercial production of highly purified single peak and single component insulin. The routine use of these pre9ara -tions have reduced insulin allergy and abolished insulin lipo­atrophy.  The subject of low dose insulin infusion in diabetic keto - acidosis in still controversial,but is based on sound theoreti - cal and experim...

متن کامل

Intelligent blood glucose control in diabetic patients: design and simulation of an artificial pancreas

Background: Diabetes mellitus (DM) is a common chronic disease with diverse complications. About 10% of the earth's population suffer from this disease. For smart control of the blood glucose in DM patients, an artificial pancreas was designed and simulated by a predictive sliding mode controller considering the time delay of insulin effect. Method: In this method, one of the time-delay glucos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2011