Improvement of amperometric transducer selectivity using nanosized phenylenediamine films
نویسندگان
چکیده
In this work, we studied the conditions of deposition of a semipermeable polyphenylenediamine (PPD)-based membrane on amperometric disk platinum electrodes. Restricting an access of interfering substances to the electrode surface, the membrane prevents their impact on the sensor operation. Two methods of membrane deposition by electropolymerization were compared-at varying potential (cyclic voltammetry) and at constant potential. The cyclic voltammetry was shown to be easier in performing and providing better properties of the membrane. The dependence of PPD membrane effectiveness on the number of cyclic voltammograms and phenylenediamine concentration was analyzed. It was shown that the impact of interfering substances (ascorbic acid, dopamine, cysteine, uric acid) on sensor operation could be completely avoided using three cyclic voltammograms in 30 mM phenylenediamine. On the other hand, when working with diluted samples, i.e., at lower concentrations of electroactive substances, it is reasonable to decrease the phenylenediamine concentration to 5 mM, which would result in a higher sensitivity of transducers to hydrogen peroxide due to a thinner PPD layer. The PPD membrane was tested during continuous operation and at 8-day storage and turned out to be efficient in sensor and biosensors.
منابع مشابه
Ascorbic Acid Determination by an Amperometric Ascorbate Oxidase-based Biosensor
The aim of this work is to develop a method for ascorbic acid determination in some fruit juices, by using an ascorbate oxidase-based amperometric enzyme electrode. The enzyme was immobilized on a nylon (Biodyne A) membrane by glutaraldehyde linking. The enzyme-membrane was consecutively attached to the polyethylene membrane of a Clark oxygen electrode, which functioned as transducer. The analy...
متن کاملJaw Cancer Detection Using Nano Amperometric Biosensor with Surface Tension Variables
1. Amperometric 2. Voltametric 3. Conductometric Biosensors [1]. In amperometric biosensor, current is final output, this current is measured in terms of oxygen. Whereas in Voltametric biosensor and voltage is final output. In conductometric biosensor, thermal voltage is final output. The biosensor contains a ligand and a transducer ligand means biological element and transducer mean which conv...
متن کاملEnzyme-electropolymer-based amperometric biosensors: an innovative platform for time-temperature integrators.
A novel exogenous time-temperature integrator (TTI) based on an amperometric glucose oxidase biosensor is presented. The TTI consists of the enzyme entrapped within an electrochemically generated poly(o-phenylenediamine) (PoPD) thin film deposited on the interior wall of a platinum (Pt) or a platinized stainless steel (Pt-SS) capsule. After thermal treatment, the TTI is mounted in a continuous ...
متن کاملMicrowave excitation of spin wave beams in thin ferromagnetic films.
An inherent element of research and applications in photonics is a beam of light. In magnonics, which is the magnetic counterpart of photonics, where spin waves are used instead of electromagnetic waves to transmit and process information, the lack of a beam source limits exploration. Here, we present an approach enabling generation of narrow spin wave beams in thin homogeneous nanosized ferrom...
متن کاملAmperometric microbial biosensor for direct determination of organophosphate pesticides using recombinant microorganism with surface expressed organophosphorus hydrolase.
An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parat...
متن کامل