Interocular Asymmetry of Foveal Thickness in Parkinson Disease

نویسندگان

  • Eric M. Shrier
  • Christopher R. Adam
  • Brian Spund
  • Sofya Glazman
  • Ivan Bodis-Wollner
چکیده

Purpose. To quantify interocular asymmetry (IA) of foveal thickness in Parkinson disease (PD) versus that of controls. Design. Prospective case-control series. Methods. In vivo assessment of foveal thickness of 46 eyes of 23 PD patients and 36 eyes of 18 control subjects was studied using spectral domain optical coherence tomography (SD-OCT). Inner versus outer layer retinal segmentation and macular volumes were quantified using the manufacturer's software, while foveal thickness was measured using the raw data from each eye in a grid covering a 6 by 6 mm area centered on the foveola in 0.25 mm steps. Thickness data were entered into MATLAB software. Results. Macular volumes differed significantly at the largest (Zone 3) diameter centered on the foveola (ETDRS protocol). By segmenting inner from outer layers, we found that the IA in PD is mostly due to changes on the slope of the foveal pit at the radial distances of 0.5 and 0.75 mm (1.5 mm and 1 mm diameter). Conclusions. About half of the PD patients had IA of the slope of the foveal pit. IA is a potentially useful marker of PD and is expected to be comparable across different SD-OCT equipment. Data of larger groups may be developed in future multicenter studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal and choroidal thickness in myopic anisometropia.

PURPOSE We compared the retinal thickness (RT) and choroidal thickness (ChT) between the fellow eyes of nonamblyopic myopic anisometropes. METHODS The eyes of 22 nonamblyopic myopic anisometropes (≥ 1 diopter [D] spherical equivalent refraction [SER] anisometropia) were examined using spectral domain optical coherence tomography (SD-OCT). Customized software was used to register, align, and a...

متن کامل

Topographic variation and interocular symmetry of macular choroidal thickness using enhanced depth imaging optical coherence tomography.

PURPOSE To report and analyze factors influencing topographical and interocular variations in choroidal thickness (CT) in a healthy adult population. METHODS One hundred eyes of 50 healthy subjects underwent visual acuity and axial length measurements and optical coherence tomography (OCT) with enhanced depth imaging (EDI). CTs at the fovea and at 3 mm nasal, temporal, superior, and inferior ...

متن کامل

Intrasession Repeatability and Interocular Symmetry of Foveal Avascular Zone and Retinal Vessel Density in OCT Angiography

Purpose To measure intrasession repeatability and interocular symmetry of the foveal avascular zone area (FAZA) and superficial retinal vessel density (SRVD) using AngioVue Analytics optical coherence tomography angiography (OCTA). Methods Fifty healthy individuals were prospectively enrolled. OCTA scans (3 × 3 and 6 × 6 mm) were acquired twice in right and once in left eyes. FAZA (with and w...

متن کامل

Interocular Symmetry in Macular Choroidal Thickness in Children

Objective. To report interocular differences in choroidal thickness in children using spectral domain optical coherence tomography (SD-OCT) and correlate findings with biometric data. Methods. This observational cross-sectional study included 91 (182 eyes) healthy children aged 6 to 17 years with no ocular abnormality except refractive error. After a comprehensive eye exam and axial length meas...

متن کامل

Symmetry of optic nerve head parameters measured by the heidelberg retina tomograph 3 in healthy eyes: the Blue Mountains Eye study.

PURPOSE To assess the symmetry of optic nerve head parameters measured by the Heidelberg Retina Tomograph 3 (HRT 3) between fellow eyes in a normal elderly population. DESIGN Cross-sectional population-based study. METHODS Participants of the Blue Mountains Eye Study 10-year follow-up who did not have optic disc disease, including glaucoma, were included. Optic nerve head parameters measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012