Re-implantation of suboptimal prostate seed implantation: technique with intraoperative treatment planning
نویسندگان
چکیده
PURPOSE Post-implant dosimetry following prostate seed implantation (PSI) occasionally reveals suboptimal dosimetric coverage of the gland. Published reports of re-implantation techniques have focused on earlier-generation techniques, including preplanned approaches and stranded seeds. The purpose of this case report is to describe a customizable approach to perform corrective re-implantation using loose seeds and intraoperative planning technique. MATERIAL AND METHODS This case report describes a 63-year-old male with favorable risk prostate adenocarcinoma receiving PSI. Thirty day post-implant dosimetric evaluation revealed suboptimal coverage of the base of the gland. Using guidance from post-implant CT-images and real-time planning, the patient received a corrective re-implantation with intraoperative planning. RESULTS Post-implant dosimetry after re-implantation procedure with intraoperative planning yielded improved target volume coverage that achieved standard dosimetric criteria. CONCLUSIONS Re-implantation as a salvage treatment technique after sub-optimal PSI is a valid treatment option performed with intraoperative real-time planning.
منابع مشابه
Progressive transition from pre-planned to intraoperative optimizing seed implant: post implementation analysis
PURPOSE To perform a dosimetric comparison between a pre-planned technique and a pre-plan based intraoperative technique in prostate cancer patients treated with I-125 permanent seed implantation. MATERIAL AND METHODS Thirty patients were treated with I-125 permanent seed implantation using TRUS guidance. The first 15 of these patients (Arm A) were treated with a pre-planned technique using u...
متن کاملIodine-125 brachytherapy for localized prostate cancer and urinary morbidity: a prospective comparison of two seed implant methods-preplanning and intraoperative planning.
OBJECTIVES To compare morbidity between two currently used iodine-125 seed implantation techniques for the treatment of localized prostate cancer. METHODS Iodine-125 brachytherapy was used in 300 consecutive men with localized prostate cancer. Two seed implant techniques were used: preplanning, using preloaded needles, and intraoperative planning, using a Mick applicator. A comparison was mad...
متن کاملClinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy.
PURPOSE The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate bra...
متن کاملComparison of three different techniques of low-dose-rate seed implantation for prostate cancer
PURPOSE Three different techniques of low-dose-rate seed implantation for prostate cancer have been used since its use started in our hospital. The purpose of this study was to compare the results of the three different techniques. MATERIAL AND METHODS The data of 305 prostate cancer patients who underwent low-dose-rate seed implantation were retrospectively analyzed. Pre-plan technique (n = ...
متن کاملFocal partial salvage low-dose-rate brachytherapy for local recurrent prostate cancer after permanent prostate brachytherapy with a review of the literature
PURPOSE To investigate the treatment results for focal partial salvage re-implantation against local recurrence after permanent prostate brachytherapy. MATERIAL AND METHODS Between January 2010 and September 2015, 12 patients were treated with focal partial salvage re-implantation for local recurrence after low-dose-rate brachytherapy using (125)I seeds. The focal clinical target volume (F-CT...
متن کامل