The halo fixator.

نویسنده

  • Christopher M Bono
چکیده

The halo fixator may be used for the definitive treatment of cervical spine trauma, preoperative reduction in the patient with spinal deformity, and adjunctive postoperative stabilization following cervical spine surgery. Halo fixation decreases cervical motion by 30% to 96%. Absolute contraindications include cranial fracture, infection, and severe soft-tissue injury at the proposed pin sites. Relative contraindications include severe chest trauma, obesity, advanced age, and a barrel-shaped chest. In children, a computed tomography scan of the head should be obtained before pin placement to determine cranial bone thickness. Complications of halo fixation include pin loosening, pin site infection, and skin breakdown. A concerning rate of life-threatening complications, such as respiratory distress, has been reported in elderly patients. Despite a paucity of contemporary data, recent retrospective studies have demonstrated acceptable results for halo fixation in managing some upper and lower cervical spine injuries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails

  Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...

متن کامل

Care of external fixator pin sites.

External fixators include pins and wires placed by surgeons to stabilize fractures such as those involving the tibia. In critical care, external fixators are more commonly used to stabilize cervical spine fractures. Because halo fixators secure cervical alignment, these devices allow early mobilization and shortened stays. However, halo-fixator complications include cranial pin loosening, local...

متن کامل

بررسی اثر هاله ناخالصی کانال و شیب غلظت آن در ترانزیستور اثرمیدانی نانولوله کربنی با آلایش سبک ناحیه سورس و درین با هاله خطی

In this work, a lightly doped drain and source CNTFET with a linear channel impurity halo is proposed and the effect of linear halo slope variation on ON current, ON–OFF current ratio, leakage current, power–delay product (PDP) and cutoff frequency has been investigated. Proposed linear halo lightly doped drain and source CNTFETs has been simulated using non equilibrium Green’...

متن کامل

Vertebral Artery Caught in the Fracture Gap after Traumatic C2/3 Spondylolisthesis

BACKGROUND CONTEXT Patient with a C2 fracture and entrapment of the right vertebral artery in the fracture gap. PURPOSE Presentation of a case with follow-up until end of treatment. STUDY DESIGN Case report. METHODS A 25-year-old woman was brought into our emergency room after falling while riding a horse. She complained of pain in the cervical spine. Clinical examinations showed local te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the American Academy of Orthopaedic Surgeons

دوره 15 12  شماره 

صفحات  -

تاریخ انتشار 2007