Frequency-based analysis of the early rapid filling pressure-flow relation elucidates diastolic efficiency mechanisms.
نویسندگان
چکیده
Stiffness- and relaxation-based diastolic function (DF) assessment can characterize the presence, severity, and mechanism of dysfunction. Although frequency-based characterization of arterial function is routine (input impedance, characteristic impedance, arterial wave reflection), DF assessment via frequency-based methods incorporating optimization/efficiency criteria is lacking. By definition, optimal filling maximizes (E wave) volume and minimizes "loss" at constant stored elastic strain energy (which initiates mechanical, recoil-driven filling). In thermodynamic terms, optimal filling delivers all oscillatory power (rate of work) at the lowest harmonic. To assess early rapid filling optimization, simultaneous micromanometric left ventricular pressure and echocardiographic transmitral flow (Doppler E wave) were Fourier analyzed in 31 subjects. A validated kinematic filling model provided closed-form expressions for E wave contours and model parameters. Relaxation-based DF impairment is indicated by prolonged E wave deceleration time (DT). Optimization was assessed via regression between the dimensionless ratio of 2nd (Q2) and 3rd flow harmonics (Q3) to the lowest harmonic (Q1), i.e., (Q2/Q1) or (Q3/Q1) vs. DT or c, the filling model's viscosity/damping (energy loss) parameter. Results show that DT prolongation or increased c generated increased oscillatory power at higher harmonics (Q2/Q1 = 0.00091DT + 0.09837, r = 0.70; Q3/Q1 = 0.00053DT + 0.02747, r = 0.60; Q2/Q1 = 0.00614c + 0.15527, r = 0.91; Q3/Q1 = 0.00396c + 0.05373, r = 0.87). Because ideal filling is achieved when all oscillatory power is delivered at the lowest harmonic, the observed increase in power at higher harmonics is a measure of filling inefficiency. We conclude that frequency-based analysis facilitates assessment of filling efficiency and elucidates the mechanism by which diastolic dysfunction associated with prolonged DT impairs optimal filling.
منابع مشابه
The isovolumic relaxation to early rapid filling relation: kinematic model based prediction with in vivo validation
Abstract Although catheterization is the gold standard, Doppler echocardiography is the preferred diastolic function (DF) characterization method. The physiology of diastole requires continuity of left ventricular pressure (LVP)-generating forces before and after mitral valve opening (MVO). Correlations between isovolumic relaxation (IVR) indexes such as tau (time-constant of IVR) and noninvasi...
متن کاملDiastolic dysfunction beyond distensibility: adverse effects of ventricular dilatation.
Diastolic function has conventionally been assessed on the basis of the LV end-diastolic pressure-volume relation (Figure 1). A shift of this curve upward and to the left (curve A, Figure 1) has been considered to be the hallmark of diastolic dysfunction. In this situation, each LV end-diastolic volume is associated with a higher end-diastolic pressure, and therefore, the ventricle is less dist...
متن کاملTransmitral pressure-flow velocity relation. Importance of regional pressure gradients in the left ventricle during diastole.
Effects of regional diastolic pressure differences within the left ventricle on the measured transmitral pressure-flow relation were determined by simultaneous micromanometric left atrial (LAP) and left ventricular pressure (LVP) measurements, and Doppler echocardiograms in 11 anesthetized, closed-chest dogs. Intraventricular pressure recordings at sites that were 2, 4, and 6 cm from the apex w...
متن کاملEvaluation of LV diastolic function from color M-mode echocardiography.
OBJECTIVES this study evaluated early diastolic filling dynamics using a semiautomated objective analysis of filling velocities obtained from color M-mode echocardiography. BACKGROUND diastolic function can be evaluated from color M-mode echocardiography by measuring the early diastolic flow propagation velocity (Vp) from the slope of a single linear approximation of an isovelocity contour. H...
متن کاملImpaired left ventricular diastolic filling in patients with familial amyloid polyneuropathy: a pulsed Doppler echocardiographic study.
To assess left ventricular diastolic filling in patients with amyloid heart disease 12 patients with familial amyloid polyneuropathy and 15 normal subjects were studied by pulsed Doppler echocardiography. None of the patients had clinical evidence of overt heart disease or restrictive cardiomyopathy and only two of them showed ventricular wall thickening. The peak flow velocity of rapid diastol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 291 6 شماره
صفحات -
تاریخ انتشار 2006