Simulation of Motion-Induced Dark-Rim Artifacts for Cartesian and Spiral Pulse Sequences
نویسندگان
چکیده
Introduction: First-pass MR perfusion images may be corrupted by dark-rim artifacts, which are at least in part a consequence of myocardial motion during data acquisition [1]. We have previously shown that the non-linear time-varying displacements of the myocardium resulting from cardiac contraction result in dark-rim artifacts that have a different appearance in images obtained at different phases of the cardiac cycle for Cartesian sampling strategies [2]. We sought evaluate whether spiral trajectories which have a different temporal sampling of k-space data would be more robust to dark-rim artifacts. Methods: To have a realistic representation of cardiac motion, the radii of the epicardial and endocardial borders were measured from a short axis cine of a healthy volunteer, and fit with one cycle of a cosinusoidal wave as demonstrated previously (Fig 1)[2]. For the simulation, the heart was represented as circles of these radii that varied according to this cosinusoidal model. Data collection was simulated by sampling the kspace representation of these two circles (the sum of two jinc functions) at each k-space location according to the pulse sequence timing. The contrast between the LV and myocardium was 3:1 to simulate signal intensities when dark-rim artifacts frequently occur. The following parameters were used to simulate a typical gradient echo Cartesian pulse sequence: FOV 350x262 cm, MAT 192x91, resolution 1.8x2.9 mm, TR 2.3, parallel imaging with R=2 and 24 phase correction lines (corresponding to 59 PE lines total). The identical model of cardiac motion as above was simulated for an interleaved-spiral acquisition. Pulse sequence parameters included: FOV 320mm x 320mm, resolution 2.18 mm, 8 spiral interleaves, readout duration 8.2 ms per interleaf, TR 13ms, TE 1.8 ms. Images were simulated with acquisitions centered at 150, 200, 250, and 300ms from end diastole. Additionally, images without motion were simulated with radii corresponding to the nominal radius at the specified time points. Results: Figure 2 demonstrates simulated images obtained with Cartesian sampling without motion (top row) and with motion centered at 150, 200, 250, and 300 ms from end diastole (bottom row). In the images without motion, a dark-rim from Gibbs ringing is evident. In the simulated images with motion, the dark-rim artifact has a different appearance. During systole (150-250 ms) the myocardial border is less distinct, and the darkrim artifact appears mid-myocardial. In the images near peak systole (300ms) the myocardial border is sharper, but a dark-rim artifact appears at the endocardial border and is more pronounced. Figure 3 demonstrates images obtained with interleaved spiral sampling without motion (top row) and with motion centered at the same time points as for the Cartesian case (bottom row). As in the rectilinear case, when there is no motion, Gibbs ringing results in some dark-rim artifact. In the spiral images modeled with motion, the Gibbs ringing is still apparent, but the simulated images with motion, there is a considerable reduction in motion-induced dark-rim artifact as compared to the Cartesian case. Conclusions: Simulation of interleaved spiral data acquisition demonstrates reduced sensitivity to motion-induced dark-rim artifacts as compared to conventional Cartesian data acquisition. Thus, spiral data acquisition strategies may be advantageous for first-pass myocardial perfusion imaging. .
منابع مشابه
Adenosine stress CMR with variable density spiral pulse sequences accurately detects CAD with minimal dark-rim artifacts
Background Adenosine stress CMR perfusion imaging has numerous advantages over competing modalities for assessing CAD demonstrating high diagnostic and prognostic utility. However, adenosine stress CMR perfusion imaging is limited by motion-induced dark-rim artifacts (DRA) which may be mistaken for true perfusion abnormalities. We have previously demonstrated that a high-resolution variable-den...
متن کاملAdenosine stress CMR with spiral pulse sequences accurately detect CAD
Background Adenosine stress perfusion imaging with CMR has been limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. We have previously demonstrated that spiral pulse sequences can produce high quality first-pass perfusion images.[1] We have further improved this spiral technique using high-resolution variable density spiral trajectories and a no...
متن کاملAdenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.
BACKGROUND Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical...
متن کامل3D Spiral LGE for reduced enhancement artifacts in PV imaging of pre- and post-ablation scar
Figure 1. Demonstrations of the edge artifact observed in LGE (yellow arrow). .A-B are Bloch simulations of the Cartesian (A) and spiral LGE sequences for circles with T1 values of 300ms and 200ms (top circle and bottom circle respectively). C-D show phantom images acquired with the Cartesian LGE sequence, where the edge artifact can be observed with greater intensity for increasing acquisition...
متن کاملThe Contribution of Cardiac Motion to Dark Rim Artifacts in Myocardial Perfusion Scans
Introduction: Adenosine stress perfusion imaging is a promising method for the evaluation of coronary artery disease, but dark rim artifacts in the myocardium can mimic perfusion defects and thus reduce its accuracy. The causes of dark rim artifacts are not completely understood, with Gibb’s ringing and cardiac motion thought to be contributing factors. In this work our experimental data lends ...
متن کامل