Portable Impedance Cardiography System for Real-Time Noninvasive Cardiac Output Measurement

نویسندگان

  • Liang-Yu Shyu
  • Chia-Yin Chiang
  • Chun-Peng Liu
  • Wei-Chih Hu
چکیده

Impedance cardiography (ICG) is the only known method that can observe the continuous left ventricular volume changes non-invasively and conveniently. This paper proposes to develop a portable ICG system for long-term continuous cardiac activity monitoring using the impedance technique. This ICG system combines the advance analog amplifier with the calculation power of digital signal processing chip to achieve real-time monitoring. One of the major differences between the proposed system and the existing systems is in the bandwidth of dZ/dt circuit. Using proper bandwidth can significantly increase the reliability and validity of ICG signal. Additionally, the proposed system is light weight and suitable for a portable monitoring system.The results demonstrate that the proposed ICG system is capable of tracking the dynamic changes of SV and CO during physiological challenges such as Valsava maneuver and the hand grip task. On the other hand, the results also show that there is no difference between CO obtained by the proposed ICG system and the Fick method. Additionally, the correlation coefficient is 0.91. The results indicate that the proposed system is a valid and reliable tool for patient monitoring and it is capable of assessing the dynamic cardiac activity information.Due to the simplicities of the current signal processing and events detection methods, the CPU is idled for substantial amount of time. Thus, in the future, more advanced techniques such as adaptive filtering and wavelet analysis can be implemented for event detection to increase the accuracy and reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

Measurement of Cardiac Output using Bioimpedance Methd

Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Cardiac output is the functional expression of cardiovascular performance and can be used to confirm the need for, or usefulness of treatment. Determination of cardiac output is an important procedure in interventional cardiology and also used in cardiothora...

متن کامل

Measurement of Cardiac Output using Bioimpedance Method

Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Cardiac output is the functional expression of cardiovascular performance and can be used to confirm the need for, or usefulness of treatment. Determination of cardiac output is an important procedure in interventional cardiology and also used in cardiothora...

متن کامل

Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography.

UNLABELLED Recently, devices have become available that allow non-invasive measurement of stroke volume and cardiac output through ambulatory thorax impedance recording. If such recordings have adequate temporal stability, they offer great potential to further our understanding of how repeated or chronic cardiovascular activation in response to naturalistic events may contribute to cardiovascul...

متن کامل

Monitoring: Arterial and Pulmonary Artery Catheters

55. Treister N, Wagner K, Jansen PR. Reproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease. Am J Hypertens. 2005;18(Pt 2):44S–50S. 56. Barcarse E, Kazanegra R, Chen A, et al. Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department. Cong...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006