Contamination of equipment in emergency settings: An exploratory study with a targeted automated intervention

نویسندگان

  • Chidi Obasi
  • Allison Agwu
  • Wale Akinpelu
  • Roger Hammons
  • Clyde Clark
  • Ralph Etienne-cummings
  • Peter Hill
  • Richard Rothman
  • Stella Babalola
  • Tracy Ross
  • Karen Carroll
  • Bolanle Asiyanbola
چکیده

BACKGROUND Despite standard manual decontamination, hospital equipment remains contaminated with microorganisms, contributing to nosocomial transmission and hospital acquired infections. This has the potential to negate the effects of healthcare workers' hand-washing protocols. In order to decrease the likelihood of equipment contamination, there has been a rise in the use of disposable pieces of equipment, especially non-critical disposables. However, these carry a significant cost, both a direct financial cost (running into billions of dollars), as well as a cost to the environment. This is important because we hope to contain the cost of healthcare, one way to do that, is to look to the hospitals themselves, for innovative solutions that maintain the standard of care. OBJECTIVE To develop and evaluate the effectiveness of an simple decontamination device for use with portable hospital equipment, by comparing rates of residual contamination after use of the novel device versus those seen with standard manual decontamination methods. METHODS The Self-cleaning Unit for the Decontamination of Small instruments (SUDS) is a user-friendly, automated instrument developed via multi-disciplinary collaboration for decontamination in the clinical area. Pre- and post- utilization of portable medical equipment in an emergency department (ED) setting were cultured. To evaluate durability of the decrease in antimicrobial contamination, objects were re-cultured 48 hours after SUDS cleaning and following re-introduction into the clinical setting. RESULTS After manual decontamination, 25% (23/91) of the tested objects in the ED were found to be culture positive with clinically significant microorganisms(CSO). Fifteen percent (ED) of non-critical equipment tested had multiple organisms. Following the use of SUDS, the colonization rate decreased to 0%. Following SUDS treatment and re-introduction into the clinical settings, after 48 hours the contamination rates as reflected by the cultures remained 0%. CONCLUSION Standard non-critical equipment is contaminated with clinically significant microorganisms. The SUDS device allows for effective and durable decontamination of hospital equipment of varying sizes in the clinical area without disrupting patient care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The prevalence of Staphylococcus aureus contamination in the ambulances and on-call emergency medical service personnel of Kashan city in Iran

Objective: Emergency medical services systems are at the first line of dealing with patients who suffer from various infections. Conducting investigations on the bacterial contamination of emergency ambulances play a crucial role to improve the occupational health of staff as well as the quality of patient care. Therefore, the aim of the present study was to investigate the presence of Staphylo...

متن کامل

Evaluation of emergency equipment and drugs in Karaj urban dental clinics and the ability of dentists to use them

Evaluation of emergency equipment and drugs in Karaj urban dental clinics and the ability of dentists to use them Dr. M. Bayat* - Dr. L. Malkamian** - Dr. F. Baheri*** *- Assistant Professor of Oral and Maxillofacial Surgery Dept. - Faculty of Dentistry–Tehran University of Medical Sciences. **- Assistant Professor of Statistics Dept. Faculty of Medicine – Tehran University of Medical Sciences....

متن کامل

Reducing blood culture contamination in the emergency department: an interrupted time series quality improvement study.

OBJECTIVES Blood culture contamination is a common problem in the emergency department (ED) that leads to unnecessary patient morbidity and health care costs. The study objective was to develop and evaluate the effectiveness of a quality improvement (QI) intervention for reducing blood culture contamination in an ED. METHODS The authors developed a QI intervention to reduce blood culture cont...

متن کامل

رتبه بندی عوامل موثر بر آمادگی اورژانس ‌های پیش ‌بیمارستانی از دیدگاه کارکنان عملیاتی اورژانس مازندران

Background and purpose: In urban health care system, pre-hospital emergency medical services are the first line to deal with critical patients. If a fast and accurate medical care is delivered, deaths and disabilities resulting from diseases reduce and trust of people to this system will increase. The purpose of this study was to determine the factors influencing the readiness of pre-hospital e...

متن کامل

Exploring undergraduate medical students’ perception of learning procedural skills and its outcomes in clinical settings

Introduction: Learning procedural skills is one of the essentialaspects of undergraduate medical education. However, learningprocedural skills in clinical settings is less widely considered.This study aimed to explore the Iranian undergraduate medicalstudents’ perception of learning procedural skills and its outcomesin three universities of medical sciences in Iran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of Surgical Innovation and Research

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009